Infectivity of dried coliphage T1 has been measured as a function of humidity, temperature, and atmospheric pressure. Loss of infectivity by a factor of 10(4) was caused by water vapor of approximately 40 to 85% saturation when the microorganisms were kept for 3 days at 34 C in evacuated containers. At humidities below 40% and above 90% saturation, no loss of infectivity occurred. At a temperature of 24 C, the infectivity loss was 20-fold. When the virus preparation was kept at 34 C and atmospheric pressure, some loss of infectivity was also found at humidities below 40% and above 90% saturation. Damage to tail proteins or to the phage chromosome is considered as a possible explanation for the inactivation.
منابع مشابه
Survival of T3 coliphage in varied extracellular environments. I. Viability of the coliphage during storage and in aerosols.
The objective of this study was to determine the feasibility of using airborne T3 coliphage as a viral tracer in microbial aerosols. Although T3 coliphage was relatively stable when stored either at temperatures ranging from 21 to 37 C or in the frozen state at -20 C, there was a 2-log loss in infectivity when stored for 72 days at 4 C. Either agitation of stored coliphage suspensions held at 3...
متن کاملThe Effect of Dried Poultry Droppings Levels Supplementation on Body Linear Measurements of Growing Rams Fed with Sorghum Stover
Effect of dietary treatment levels on body linear measurements of growing Yankasa rams (Ovis aries) fed sorghum (Sorghum bicolor)Moench stover supplemented with graded levels of dried poultry dropping based diets was assessed using thirty growing Yankasa rams (Ovis aries) consisting of five treatments (T1-T5). Each treatment consisted of three replicates with two animals per replicate. T1: were...
متن کاملCharacteristics of dried Serratia marcescens in the airborne state.
Although there have been many studies of the endurance and infectivity of bacteria atomized from liquid menstrua to simulate, for one purpose, the behavior of bacteria spread by coughs and sneezes (Wells, 1955), few studies of powdered bacterial aerosols have been reported. The latter appears to simulate airborne dusts from roads, floors, bedding, and fomites in general, and is, therefore, of p...
متن کاملHigh Humidity Leads to Loss of Infectious Influenza Virus from Simulated Coughs
BACKGROUND The role of relative humidity in the aerosol transmission of influenza was examined in a simulated examination room containing coughing and breathing manikins. METHODS Nebulized influenza was coughed into the examination room and Bioaerosol samplers collected size-fractionated aerosols (<1 µM, 1-4 µM, and >4 µM aerodynamic diameters) adjacent to the breathing manikin's mouth and al...
متن کاملA Sensitive Neutralization Assay for Influenza C Viruses Based on the Acetylesterase Activity HEF Glycoprotein
Influenza C virus possesses specific neuraminate-O-acetylesterase as a receptor-destroying function. This enzymatic activity of the viral glycoprotein HEF (Hemagglutinin, esterase activity and fusion factor) can be visualized in situ by the use of distinct color substrates. Hereby the localization, as well as the quantity of synthesized HEF protein is detectable. We further developed the estera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied microbiology
دوره 16 10 شماره
صفحات -
تاریخ انتشار 1968