Developing an algorithm to convert routine measures of vision into utility values for glaucoma.

نویسندگان

  • Yasmene Alavi
  • Mireia Jofre-Bonet
  • Catey Bunce
  • Richard P Wormald
  • Ananth Viswanathan
  • Allen Foster
  • Roger Hitchings
چکیده

PURPOSE Measures of quality of life called utility values (UVs) are needed to deliver the most cost-effective health care for glaucoma patients. UVs are rarely measured in clinical research and practice whereas clinical outcomes such as visual field are routinely collected. The aim of this study was to develop an algorithm that calculates UVs directly from combinations of routine measures of binocular visual field, visual acuity, and contrast sensitivity. METHODS A total of 132 outpatients with primary open angle glaucoma were recruited. The Time Trade-off (TTO) question was administered during face-to-face interviews. Binocular ETDRS logMAR visual acuity (VA(B)), binocular Pelli-Robson contrast sensitivity (CS(B)), and Humphrey 24-2 monocular visual field tests were performed on the same day. Integrated (binocular) visual field (IVF) scores were derived. Tobit regression analyses were used to model utility values based on combinations of IVF, VA(B), CS(B) and other controlling factors. RESULTS UVs recorded for 123 cases correlated significantly with both clinical measures of binocular visual function (r = -0.47, IVF; r = -0.48, VA(B); r = 0.50, CS(B); P <0.0001) and measures of vision-specific quality of life (r = 0.54-0.6, P <0.0001). Two final models incorporate terms for IVF and VA(B), with or without living arrangements, and explain 22% and 31% of variation in utilities. CS(B) was not included in either model due to co-linearity between CS(B) and VA(B) confounding the models. CONCLUSION The models provide preliminary algorithms for predicting the expected UVs for glaucoma populations directly from clinical outcomes collected routinely in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a New Algorithm for a Utility-based Network Design Problem with Elastic Demand

Developing the infrastructures for preventing non-communicable diseases is one of the most important goals of healthcare context in recent years. In this regard, the number and capacity of preventive healthcare facilities as well as assignment of customers to facilities should be determined for each region. Besides the accessibility, the utility of customers is a determinative factor in partici...

متن کامل

Developing a preference-based Glaucoma Utility Index using a discrete choice experiment.

PURPOSE To estimate a utility-based glaucoma health outcome measure, known as the Glaucoma Utility Index. METHODS Based on focus group studies, involving people with glaucoma, existing profile measures relevant to glaucoma were modified and a six-dimensional profile instrument was developed. Dimensions were: central and near vision; lighting and glare; mobility; activities of daily living; ey...

متن کامل

Utility Estimation of Health Status of Cancer Patients by Mapping for Cost-Utility Analysis

Background: It is important to obtain accurate information about the preferences of people for measuring quality-adjusted life years (QALYs), because it is necessary for cost-utility analysis. In this regard, mapping is a method to access this information. Therefore, the purpose of this study was to map Functional Assessment of Cancer Therapy – General (FACT-G) onto Short Form Six Dimension (SF...

متن کامل

Using Ahmed’s Gonioimplant Valve to Surgical Treatment of Glaucoma in Two Dogs

Case Description- An eleven-year-old Golden retriever male dog (dog I) and a four-year-old neutered Toy Terrier (dog II) were referred to Small Animal Clinic. Dog I was suffered from   partial loss of vision and engorgement of episcleral vessels of his right eye and dog II was blind. Intraocular pressure (IOP) of right eye was 37.8 mmHg in dog  I  and 34.5 and 31.6 mmHg in the right and left...

متن کامل

Evaluation of Retinal Optic Disc Segmentation in Patients with Glaucoma and Comparison with Other Methods of Medical Image Processing

Introduction: Glaucoma is the most common cause of blindness in some countries. In the meantime, the field of retinal image processing has been proposed in order to provide automatic systems for disease diagnosis. Among the methods of medical image processing, image segmentation is a process of identification and change in the display of an image. The objective of this study was to use t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic epidemiology

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2011