Safety butterfly needles for blood drawing.
نویسندگان
چکیده
To the Editor: Despite safety recommendations, the increased availability of personal protective equipment, and the implementation of improved disposal systems, high-risk needlestick injuries continue to occur in unacceptably high numbers in healthcare settings.1 Design features of needle devices are relevant to their high injury risk. For example, butterflytype devices with needle-shielding features to protect against needlestick injuries showed a 25% reduction in needlesticks in a clinical trial.2 Any other risk-reducing design enhancements that can be incorporated into butterfly-type devices should be promoted and evaluated, particularly those intended for blood drawing, because of their disproportionate involvement in the transmission of bloodborne pathogens. In a recent study on devicespecific sharps injuries among healthcare workers, of all hollow-bore needles, conventional butterfly needles were associated with the highest injury rate per 100,000 devices used.3 This finding is consistent with the high rate of injury from butterfly-type needles documented in the Italian study on occupational risk of human immunodeficiency virus (HIV) that we reported previously.4 Since 1994, our data collection has been expanded to include all occupational exposures, regardless of source patient status, using the Exposure Prevention Information Network surveillance system.5 Of a total of 7,240 percutaneous injuries reported through December 31, 1996, 2,079 (29%) injuries were caused by butterfly-type needles. Our data show that more high-risk injuries (those involving blood-filled hollow-bore needles) are caused by butterfly-type needles than by any other device.1,4 Butterfly-type needles are notorious for producing the “cobra effect” against users when the spiral tubing recoils during disassembly and disposal. This is due to the length of the tubing and the fact that it is wound in a tight coil in its package. Although butterfly-type needles were designed primarily for intravenous therapy, they are used primarily for blood drawing. In the above-mentioned study, the highest use of butterfly-type needles was among laboratory phlebotomists. Similarly, in 569 (27%) butterfly-related needlesticks reported in the Italian Study on Occupational Risk of HIV— Exposure Prevention Information Network study, the device was used to draw blood, and 176 (31%) of these incidents occurred while putting the butterfly into a disposal container. These data demonstrate that, in relation to current practice, butterflytype devices frequently are used for blood drawing, a different procedure than that for which they were designed. We suggest that butterflytype devices intended for blood drawing should have only a short length of tubing and that the tubing should not be packaged in coils. The effectiveness of these kinds of devices should be evaluated.
منابع مشابه
Hollow-bore needlestick injuries in a tertiary teaching hospital: epidemiology, education and engineering.
OBJECTIVE To describe the frequency, cause and potential cost of prevention of hollow-bore dirty needlestick injury (NSI) sustained by healthcare workers. DESIGN AND PARTICIPANTS Ten-year prospective surveillance study, 1990-1999, with triennial anonymous questionnaire surveys of nursing staff. SETTING 800-bed university tertiary referral hospital in Brisbane, Australia. MAIN OUTCOME MEAS...
متن کاملOSHA on phlebotomy disposal.
he Occupational Safety and Health Administration (OSHA) recently issued a safety and health information bulletin explaining its policy on the disposal of contaminated needles and blood tube holders following blood-drawing procedures. The bulletin is not a standard or regulation and creates no new legal obligations. Rather, it is advisory in nature and is intended to assist employers in providin...
متن کاملUse of butterfly needles to draw blood is independently associated with marked reduction in hemolysis compared to intravenous catheter.
OBJECTIVES Hemolysis of blood samples drawn in the emergency department (ED) is a common problem that can interfere with timely diagnosis and appropriate treatment. The objective of this study was to identify the smallest number of remediable factors that independently increases the risk of hemolysis to design an effective strategy to address this issue. METHODS This was a prospective, observ...
متن کاملPreanalytical variability in laboratory testing: influence of the blood drawing technique.
The predominant technique used to draw blood for laboratory testing is a conventional straight needle attached to an evacuated tube system. However, alternative tools might be advantageous in exceptional circumstances. The use of butterfly devices has been traditionally discouraged for reasons of costs and due to the high risk of obtaining unsuitable samples, but there is no convincing evidence...
متن کاملA prospective, within-patient comparison between metal butterfly needles and Teflon cannulae in subcutaneous infusion of drugs to terminally ill hospice patients.
We performed a prospective study of hospice in-patients requiring a syringe driver (SD), to determine the site duration and tolerability of metal butterfly needles compared to Teflon cannulae. Using patients as their own control, prescribed medications were divided equally between two SDs (Graseby MS16a), for delivery over 24 h. A butterfly infusion (Flosafer, 25 gauge) was connected to one SD ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Infection control and hospital epidemiology
دوره 19 5 شماره
صفحات -
تاریخ انتشار 1998