The design of a simple, fast and accurate sample and hold circuit using a switched op-amp configuration is presented. The unique characteristic of this sample and hold circuit is the cancellation of charge injection effects due to the symmetrical output switched transistors circuit and device configuration. The clock-feed through effect is also reduced by applying the effect of clock pulses to the sources of the main output switched transistors. The circuit is designed using a 2.6 V supply at a clock frequency of 1 MHz. The output error due to an input signal of 1 V peak to peak at frequencies of 20 KHz and 100 KHz is less than 0.25 mV and 0.6mV respectively. Simulation results of second harmonic distortion using 0.25μm CMOS technology at input frequencies of 20 KHZ and 100 KHz is 86 dB and 72.5 dB below the signal level respectively at 1 volt peak to peak input.
منابع مشابه
Low-Power Circuit Techniques for Low-Voltage Pipelined ADCs Based on Switched-Opamp Architecture
This paper proposes useful circuit structures for achieving a low-voltage/low-power pipelined ADC based on switched-opamp architecture. First, a novel unity-feedback-factor sample-and-hold which manipulates the features of switched-opamp technique is presented. Second, opamp-sharing is merged into switched-opamp structure with a proposed dual-output opamp configuration. A 0.8-V, 9-bit, 10-Msamp...
متن کاملA CMOS Mixed-Mode Sample-and-Hold Circuit for Pipelined ADCs
This paper describes the design of a high-speed CMOS sampleand-hold (S/H) circuit for pipelined analog-to-digital converters (ADCs). This S/H circuit consists of a switched-capacitor (SC) amplifier and a comparator to generate the mixed-mode sampled output data, which are represented both in analog and digital forms. The mixed-mode sampling technique reduces the operational amplifier (op amp) o...
متن کاملDesigning of Current Mode Instrumentation Amplifier for Bio-signal Using 180nm Cmos Technology
In this paper we have describes the design of current mode instrumentation amplifier (CMIA) for bio-signal Acquisition system. The current mode instrumentation amplifier technology is based on voltage mode operational amplifier (op amp) power supply current sensing technique. There are two design challenges of this topology. First one is the Op amp mismatch and second is precise current mirrors...
متن کاملA 1.8V Sample-and-Hold with Reduced Flicker Noise
In this paper, CMOS Sample-and-Hold (S/H) is presented. The S/H circuit is an important component in Analog-to-digital Converter (ADC). In low frequency application, the boost clock technique is used to constitute a rail-to-rail signal voltage with low distortion. The operational amplifier works as a unity gain buffer in the S/H circuit. However, a two-stage op-amp is proposed with enhanced low...
متن کاملLow-Noise and Low-Voltage Circuit Techniques for CMOS Analog Design
1. Introduction A system on chip (SoC), which has various functions on a LSI, has been developed for a variety of applications by the submicron technologies. Especially, implantable and/or attachable neural sensor chips, which are implemented by the SoC, attract a lot of interest [1]. The neural sensor chip, which includes with a low-noise amplifier, analog-to-digital converter (ADC), transceiv...