Successful retrieval of 29 ALN inferior vena cava filters at a mean of 25.6 months after placement.

نویسندگان

  • Olivier Pellerin
  • Massimiliano di Primio
  • Olivier Sanchez
  • Guy Meyer
  • Marc Sapoval
چکیده

PURPOSE To prospectively evaluate the outcomes of ALN inferior vena cava (IVC) filter extractions after long-term implantation (ie,>1 y). MATERIALS AND METHODS Between November 2004 and January 2011, 503 retrievable ALN IVC filters were implanted, but only 188 (37%) were addressed for removal. Because it was suspected that a subset of patients had not been referred for IVC filter retrievals, between November 2008 and January 2011, all patients who still had an ALN filter that had been implanted at least 1 year previously were systematically recalled. For those patients, the relative benefits and risks of filter removal were evaluated by a multidisciplinary conference. If deemed necessary by the conference, filter removals were performed. The endpoints were the feasibility and safety of filter retrieval, which were based on an evaluation of the success rates, pre- and postprocedure complications, and dosimetric assessments. RESULTS Twenty-nine patients still retained their filters at least 1 year following implantation. The mean interval between implantation and retrieval was 25.6 months (range, 14.8-40.8 mo), and extractions were performed on eight patients who had received a filter at least 2 years earlier. The longest dwell time was 40 months. All filters were extracted successfully without complications. CONCLUSIONS Optional ALN filter retrievals can be performed safely after more than 1 year following implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total laparoscopic retrieval of inferior vena cava filter

While there is some local variability in the use of inferior vena cava filters and there has been some evolution in the indications for filter placement over time, inferior vena cava filters remain a standard option for pulmonary embolism prophylaxis. Indications are clear in certain subpopulations of patients, particularly those with deep venous thrombosis and absolute contraindications to ant...

متن کامل

The Successful Removal of Two Retrievable Inferior Vena Cava (IVC) Filters after 67 Days in a Patient with a Double IVC

We herein present a case in which two retrievable inferior vena cava (IVC) filters, which were implanted to treat deep-vein thrombosis caused by the compression of a double IVC, were successfully removed on the 67th day after placement. The filters were individually placed in both the left and right IVCs. With a prevalence of only 0.2%, a double IVC is an extremely rare anatomical variation. Th...

متن کامل

Retrievable Inferior Vena Cava Filters in Patients with Cancer: Complications and Retrieval Success Rate

Active cancer (ACa) is strongly associated with venous thromboembolism and bleeding. Retrievable inferior vena cava filters (RIVCF) are frequently placed in these patients when anticoagulation cannot be continued. Objectives. To describe the complications and retrieval rate of inferior vena cava filters in patients with ACa. Methods. Retrospective review of 251 consecutive patients with RIVCF i...

متن کامل

The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation

Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...

متن کامل

Venous thromboembolism after retrieval of inferior vena cava filters.

PURPOSE To determine the incidence of venous thromboembolism (VTE) after removal of retrievable inferior vena cava (IVC) filters. MATERIALS AND METHODS Retrospective study was conducted of 67 patients who underwent 72 consecutive filter retrievals at a single institution. Data collected included VTE status at the time of filter placement, anticoagulant medications at the time of filter retrie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 24 2  شماره 

صفحات  -