Experimental Evaluation of the Seismic Performance of Hospital Sprinkler Systems

نویسنده

  • Monica Kar Chan
چکیده

This paper discusses the experimental set-up and procedures for the seismic testing and evaluation of a sprinkler system in hospital model. Concrete compression tests are ran to ensure compliance with ACI 355.2 anchor testing qualifications. Maximum shear strength of the anchor is found to include within the piping system model. Frame and piping system within the model is tested under input motions as guided by AC 156.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical evaluation of sprinkler irrigation systems implemented in Khorram Abad city

The lack of water resources in Iran has increased concern about water consumption in the country. The agricultural sector is known as the largest sector of water consumption, and saving in this sector will save significant water resources. One of the solutions for the optimal use of water resources is the use of modern irrigation methods with proper design and implementation. Therefore, the pur...

متن کامل

Evaluation of the Effect of Connection between RC Shear Wall and Steel Moment Frame on Seismic Performance and Reduction Factor in Dual Systems

Dual systems of steel moment frame and reinforced concrete shear wall have combined the advantages of steel frames and reinforced concrete shear wall. These walls have increased the lateral stiffness of steel frames and have reduced seismic demands on steel frames thus providing opportunities to use such system. In this research intermediate dual system of steel moment frame was chosen with int...

متن کامل

Performance Evaluation of Curved-TADAS Damper on Seismic Response of Moment Resisting Steel Frame

In this study, the performance of triangular added damping and stiffness (TADAS) dampers combined with curved dampers (Curved-TADAS damper) is evaluated in moment resisting steel frame (MRSF). These dampers are passive and install in the beam-column connection region. Variable parameters of this study involve the width of curved damper (50, 75 and 100 mm), the thickness of TADAS damper (5 and 1...

متن کامل

Piping Fragility Composed of Different Materials by Using OpenSees Software

A failure of the non-structural component can cause significant damages in critical facilities such as nuclear power plants and hospitals. Historically, it was reported that the damage from the leakage of sprinkler systems, resulted in the shutdown of hospitals for several weeks by the 1971 San Fernando and 1994 North Ridge earthquakes. In most cases, water leakages were observed at the cross j...

متن کامل

Evaluation of Seismic Vulnerability of Reinforced Concrete Buildings Adjacent to the Deep Excavations

In this study, the effect of deep excavation on the seismic response of RC moment resisting building systems has been studied. Deep excavation can cause significant changes in the stress and strain levels of soil environment and also changes in the propagation of seismic waves. This leads to permanent displacements in the foundation system. In this study, three RC building systems, i.e. 5, 10, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011