A quantitative method for blood lipoproteins using cellulose acetate electrophoresis.
نویسندگان
چکیده
A rapid, inexpensive, and quantitative method is described for obtaining the levels of plasma very low, low, and high density lipoproteins using cellulose acetate electrophoresis and lipid assays without prior separation by ultracentrifuge or other techniques. It involves separation of the lipoproteins by cellulose acetate electrophoresis, followed by their identification with the ozone-Schiff reaction. The total lipoprotein concentration is estimated from the total plasma phospholipid, and the percentage of each component obtained by densitometric analysis of the stained electrophoretograms, using reflected light. For samples with a raised level of very low density lipoprotein, plasma triglyceride analysis is also required. The results obtained by the cellulose acetate electrophoresis method are in good agreement with those by the analytical ultracentrifuge and the preparative ultracentrifuge with refractometry. The theoretical assumptions on which the method is based have been shown to be valid.
منابع مشابه
Rapid large-scale screening of blood proteins by use of cellulose acetate electrophoresis on a solid support.
We describe a new principle of cellulose acetate electrophoresis (solid-support electrophoresis), in which cellulose acetate membranes are given a solid support, instead of being suspended as heretofore. The new technique is particularly well suited for screening procedures, because many samples can be processed economically on a single run. Also described for the first time, in conjunction wit...
متن کاملDetection of cryoglobulins in serum of Caspian miniature horse
Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was perform...
متن کاملComparative analysis of cellulose acetate hemoglobin electrophoresis and high performance liquid chromatography for quantitative determination of hemoglobin A2
BACKGROUND The present study is designed to evaluate the reliability and cost effectiveness of cellulose acetate Hb electrophoresis and high performance liquid chromatography (HPLC) in the determination of HbA2 levels. METHODS The test population comprised 160 individuals divided into four groups: normal individuals, β-thalassemia trait (BTT) patients, iron deficiency anemia (IDA) patients, a...
متن کاملRapid differentiation of polypeptide chains of hemoglobin by cellulose acetate electrophoresis of hemolylsates.
I DENTIFICATION of the abnormal polypeptide chain of a hemoglobin ( Hb ) variant is often useful in connection with structural analyses and Chernoff and Pettit’ have recently improved on existing methods for this purpose by using starch gel electrophoresis of globin in urea barbital buffer. Izzo2 used this same buffer for electrophoresis of globin on cellulose acetate. Ohba et al.3 have propose...
متن کاملHaemoglobin electrophoresis on cellulose acetate using whole blood samples.
A modification of the method of haemoglobin electrophoresis using cellulose acetate membrane described by Kohn (1969) enables whole blood to be applied direct to the membrane instead of a haemolysate. The method gives results which are indistinguishable from those obtained using a haemolysate. Normal protein stains are not recommended, because of interference from plasma proteins, but the metho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 24 9 شماره
صفحات -
تاریخ انتشار 1971