Cobra-Like Deformation of Amplatzer Devices Used for Closing Atrial Septal Defects: Can It Be Avoided?

نویسندگان

  • Rodrigo Estévez - Loureiro
  • Isaac Martínez - Bendayan
  • Jorge Salgado - Fernández
  • Fernando Rueda - Núñez
چکیده

We report the case of a 72-year-old woman diagnosed with ostium secundum atrial septal defect (OS-ASD) in an echocardiogram performed as part of the work-up for her high blood pressure. Over time, progressive dilation of the right ventricle was observed with progressive functional deterioration, indicating closure of the defect. Transesophageal echocardiography (TEE) confirmed an OS-ASD of 15×12 mm and it was determined that the defect was amenable to closure using a percutaneous device. The procedure was performed under general anesthesia and TEE monitoring. Vascular access was via the right femoral vein. The size of the occluder device was defined using a balloon catheter with the stop-flow technique, whereby the diameter of the occluder device is chosen to correspond to balloon diameter at the moment an absence of shunt is observed. Based on this technique, it was decided to use a 24 mm Amplatzer type device (Amplatzer Septal Occluder, AGA Medical, Golden Valley, Minnesota, USA). The discrepancy with the initial size of the ASD was due to an excessively mobile posterior edge. In our laboratory we usually use a wider sheath diameter than that recommended by the manufacturer, but the appropriate size was not available. We therefore opted for a delivery system with a 9F sheath (diameter recommended by the manufacturer). However, after inserting the device a few centimeters, significant resistance was encountered and the device had to be retracted. It was also impossible to progress using a 10F sheath (Superarrow Flex, Arrow Inc., Reading, Pennsylvania, USA), so we eventually decided to switch to a 13F sheath (Mullins, Cook Europe, Bjaeverskov, Denmark). It was possible to advance with this sheath without encountering resistance; however, when the device was deployed distally in the left atrium, a 'cobra-like' configuration was observed (Figure 1A). This configuration was maintained after retracting the device (Figure 1B), although by slightly stretching the distal portion it was possible to regain the usual shape. The device was reintroduced without problems but again assumed a 'cobra-like' configuration. However, by making small back-and-forwards movements in the sheath it was possible to normalize the shape of the device and successfully close the atrial defect (Figure 2). The 'cobra-like' configuration of the Amplatzer device is a rare but known complication of percu-taneous treatment of atrial septal defects that occurs in 0-3% of published series. It is in fact the extreme variant of a series of distortions deriving from a change in position of …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

[Correction of the perpendicular positioning of the Amplatzer device during closure of an ostium secundum atrial septal defect].

INTRODUCTION AND OBJECTIVES Ostium secundum atrial septal defects require closure. Echocardiographic studies have reported that, in 7% of cases, the Amplatzer occluder is orientated perpendicular to the rim of the defect. This article describes the use of an ancillary technique involving a balloon catheter that enables the Amplatzer device to be positioned transversely. METHODS We report six ...

متن کامل

Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

متن کامل

Percutaneous closure of multiple secundum atrial septal defects using 3 amplatzer atrial septal occluder devices: evaluation by live transthoracic 3-dimensional echocardiography.

A previously healthy 12-year-old boy was admitted to the hospital with acute pneumonitis. On admission, a heart murmur was detected. The transthoracic echocardiogram showed multiple secundum atrial septal defects with left-toright shunt and signs of right ventricular volume overload. He underwent right cardiac catheterization and transesophageal echocardiogram (transesophageal echocardiography)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017