Value of myocardial defect size measured by thallium-201 SPECT: results of a multicenter trial comparing heparin and a new fibrinolytic agent.
نویسندگان
چکیده
In a multicenter randomized double-blind trial comparing heparin and a new fibrinolytic agent, anisoylated plasminogen streptokinase activator complex (APSAC), 231 patients presenting with a less than 5 hr acute myocardial infarction underwent a contrast angiography (CA) before the end of the first week of admission, and radionuclide cardiac blood-pool imaging and a 201Tl single photon emission computed tomography (SPECT) study before the end of the third week. Left ventricular ejection fraction (LVEF) and a wall motion score (WM) were calculated from CA. LVEF was also obtained from cardiac blood-pool imaging, and defect size (DS) from 201Tl SPECT. Results demonstrated that all parameters were significantly improved in patients treated with APSAC versus heparin (contrast LVEF 53 +/- 13 vs. 47 +/- 14 p less than 0.01, WM 9.8 +/- 6.5 vs. 13.3 +/- 7.9 p less than 0.001, radionuclide LVEF 43 +/- 12 vs. 40 +/- 13 p less than 0.05, DS 14 +/- 12 vs. 18 +/- 14 p less than 0.05). When the patients were divided according to infarct site and infarct-related coronary artery patency, it was demonstrated with all four parameters that the beneficial effect of APSAC can be largely explained by the lower incidence of vessel obstruction in this group (37% vs. 77% in the heparin group, p less than 0.001). It is concluded that (a) when compared with heparin and in the conditions of the trial, APSAC significantly improves the cardiac function and decreases the DS and (b) DS measured by 201Tl SPECT is as valuable a quantitative parameter of therapeutic evaluation as are LVEF and WM.
منابع مشابه
Submaximal exercise thallium-201 SPECT for assessment of interventional therapy in patients with acute myocardial infarction.
Submaximal thallium-201 stress testing has been shown to provide important diagnostic and prognostic information in patients with acute myocardial infarction. The purpose of this investigation was to evaluate the diagnostic value of early submaximal stress testing and thallium-201 single photon emission computed tomography (SPECT) after interventional therapy. Scintigraphic results from 56 pati...
متن کاملTHERAPY AND PREVENTION THROMBOLYSIS Global and regional left ventricular function and tomographic radionuclide perfusion: The Western Washington Intracoronary Streptokinase In Myocardial Infarction Trial
The Western Washington Intracoronary Streptokinase In Myocardial Infarction Trial enrolled 250 patients with acute myocardial infarction. After the coronary angiographic diagnosis of thrombosis, patients were randomly assigned to receive either conventional therapy with heparin or intracoronary streptokinase followed by heparin. Of the 232 patients who survived at least 60 days, 207 (89%) under...
متن کاملMeasurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon - emission computed tomography , thallium - 201 , and indium 111 - monoclonal antimyosin
Single photon-emission tomography (SPECT) and indium 1ll-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous inje...
متن کاملMeasurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon - emission computed tomography , thallium - 201 , and indium 111 - monoclonal
Single photon-emission tomography (SPECT) and indium 1ll-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous inje...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 29 9 شماره
صفحات -
تاریخ انتشار 1988