The accuracy and timeliness of a Point Of Care lactate measurement in patients with Sepsis

نویسندگان

  • Fatene Ismail
  • William G. Mackay
  • Andrew Kerry
  • Harry Staines
  • Kevin D. Rooney
چکیده

BACKGROUND The aims of this study were to a) compare the lactate measurement of a Point of Care (POC) handheld device to near patient blood gas analysers, and b) determine the differential reporting times between the analysers. METHODS A two-staged study; method comparison and prospective observational stages, was conducted. For the first stage, blood samples were analysed on the i-STAT handheld device and the near patient blood gas analysers (GEM 4000 and OMNI S). Results were compared using Pearson correlation coefficient and Bland-Altman tests. For the second stage, we examined the differential reporting times of the POC device compared to the near patient blood gas analysers in two Scottish hospitals. Differential reporting times were assessed using Mann-Whitney test and descriptive statistics were reported with quartiles. RESULTS Highly significant Pearson correlation coefficients (0.999 and 0.993 respectively) were found between i-STAT and GEM 4000 and OMNI S. The Bland-Altman agreement method showed bias values of -0.03 and -0.24, between i-STAT and GEM 4000 and OMNI S respectively. Median time from blood draw to i-STAT lactate results was 5 min (Q1-Q3 5-7). Median time from blood draw to GEM 4000 lactate results was 10 min (Q1-Q3 7.75-13). Median time from blood draw to OMNIS lactate results was 11 min (Q1-Q3 8-22). The i-STAT was significantly quicker than both the GEM 4000 and the OMNIS (each p-value < 0.001). In addition, 18 of our study samples were sent to the central laboratory for analysis due to a defect in the lactate module of OMNI S. The median time for these samples from blood draw to availability of the central laboratory results at the clinical area was 133 min. CONCLUSIONS The POC handheld device produced accurate, efficient and timely lactate measurements with the potential to influence clinical decision making sooner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparison of the Point-of-Care Serum Procalcitonin Assay Method with the BRAHMS Certified Method

Background and Aims: As a method for the diagnosis and management of sepsis, the serum procalcitonin assay is routinely used, especially in the emergency department (ED) and intensive care units (ICU). Procalcitonin has reasonable diagnostic accuracy for bacteremia in hospitalized patients of all age groups with suspected infection or sepsis. This study aimed to compare the Getein Biotech proca...

متن کامل

مقایسه‌ ی کیفیت مستندات پرونده‌های پزشکی بیماران بستری در بیمارستان‌های عمومی دانشگاه علوم پزشکی ایران و تامین اجتماعی شهر تهران : 1386

Introduction: Quality of patients care is directly linked with medical documentation quality, because in all medical professions related to patient care, quality of decisions depends on information quality. Thus, in this study two main populations that offer medical care in country, Ministry of Health (MoH) and Social security Organization, were selected to measure access rate, and level of med...

متن کامل

Accuracy of Handheld Point-of-Care Fingertip Lactate Measurement in the Emergency Department

INTRODUCTION Early recognition of elevated lactate levels in sepsis may hasten the detection of those patients eligible for aggressive resuscitation. Point-of-care (POC) testing is now increasingly available for use in the emergency department (ED). We examined the accuracy and time-saving effect of a handheld POC device for the measurement of fingertip and whole blood lactate as compared with ...

متن کامل

Validating a point of care lactate meter in adult patients with sepsis presenting to the emergency department of a tertiary care hospital of a low- to middle-income country.

BACKGROUND Timely identification of high blood lactate levels in septic patients may allow faster detection of those patients requiring immediate resuscitation. Point-of-care (POC) testing is being increasingly utilized in the emergency department (ED). We examined the accuracy and time-saving effect of a handheld POC lactate device for the measurement of fingertip and whole blood lactate as co...

متن کامل

Immediate Diagnosis of Early Onset Sepsis in Premature Newborns by Measurement of Cord C-Reactive Protein and Interleukin-6

Background: The purpose of this study was to determine the relationship between early onset sepsis and increased levels of C-reactive protein (CRP) and interleukin-6 (IL-6) in cord plasma. Methods: A prospective study was conducted in 141 premature infants delivered with gestational ages of 26-35 weeks. IL-6 and CPR were measured by enzyme-linked immunoassay in the cord plasma of the neonates. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2015