High temporal and spatial resolution 3D time-resolved contrast-enhanced magnetic resonance angiography of the hands and feet.

نویسندگان

  • Clifton R Haider
  • Stephen J Riederer
  • Eric A Borisch
  • James F Glockner
  • Roger C Grimm
  • Thomas C Hulshizer
  • Thanila A Macedo
  • Petrice M Mostardi
  • Phillip J Rossman
  • Terri J Vrtiska
  • Phillip M Young
چکیده

Methods are described for generating 3D time-resolved contrast-enhanced magnetic resonance (MR) angiograms of the hands and feet. Given targeted spatial resolution and frame times, it is shown that acceleration of about one order of magnitude or more is necessary. This is obtained by a combination of 2D sensitivity encoding (SENSE) and homodyne (HD) acceleration methods. Image update times from 3.4-6.8 seconds are provided in conjunction with view sharing. Modular receiver coil arrays are described which can be designed to the targeted vascular region. Images representative of the technique are generated in the vasculature of the hands and feet in volunteers and in patient studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved angiography: Past, present, and future.

The introduction of digital subtraction angiography (DSA) in 1980 provided a method for real time 2D subtraction imaging. Later, 4D magnetic resonance (MR) angiography emerged beginning with techniques like Keyhole and time-resolved imaging of contrast kinetics (TRICKS) that provided frame rates of one every 5 seconds with limited spatial resolution. Undersampled radial acquisition was subseque...

متن کامل

Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Contrast-enhanced magnetic resonance angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3-4 mm spatial resolution with acquisition times in the 30-second range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution 3D time-resolved studies. The pu...

متن کامل

Comparison of High Spatial Resolution Time-Resolved 3D Con- trast-Enhanced MR Angiography

Introduction: Recently, computed tomographic angiography (CTA) has become widely used for lower extremity arterial runoff imaging, in part because of high spatial resolution and extended coverage obtained with continuous table movement during the exam. However, even with optimized technique, 2-3% of studies are nondiagnostic because of calcification, poor contrast opacification, or venous conta...

متن کامل

Time-resolved contrast-enhanced 3D MR angiography.

An MR angiographic technique, referred to as 3D TRICKS (3D time-resolved imaging of contrast kinetics) has been developed. This technique combines and extends to 3D imaging several previously published elements. These elements include an increased sampling rate for lower spatial frequencies, temporal interpolation of k-space views, and zero-filling in the slice-encoding dimension. When appropri...

متن کامل

Use of Parallel Imaging in Peripheral Contrast-enhanced Magnetic Resonance Angiography: Retrospective Study

Objective: To evaluate the application of a parallel imaging technique — generalised autocalibrating partially parallel acquisition — in peripheral contrast-enhanced magnetic resonance angiography. Patients and Methods: This was a retrospective review of 17 consecutive patients with peripheral vascular disease who underwent lower-extremity 3-dimensional contrast-enhanced magnetic resonance angi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2011