BACKGROUND Hypotension is one of the most common complications after spinal anesthesia for cesarean delivery. Normally, preloading with fluids, especially crystalloids, is used to prevention of hypotension. METHODS In the present randomized clinical trial study, 120 parturients presenting for elective cesarean section with the American Society of Anesthesiologists Class I and II received either 15 cc normal saline or 7 cc/kg hydroxyethyl starch 6% (Voluven) fluid. Information regarding to systolic, diastolic, mean arterial pressure, and heart rate, incidence of hypotension, adverse effects, the total dose of atropine, and ephedrine were recorded in before and 3, 6, 9, 15, and 20 min after spinal anesthesia. Furthermore, Apgar score of newborn at the 1st and 5th min after birth was recorded. RESULTS There was no significant difference in mean arterial pressure at different stages such as: Exactly after spinal and 3, 6, 15, and 20 min after spinal anesthesia between two groups (P > 0.05). Total dose of ephedrine and atropine were similar between groups (P > 0.05), respectively. There was no significant difference in Apgar score at the 1st and 5th min after birth between two groups. There were not any adverse effects of drugs in two groups. CONCLUSIONS The results of this study show that hydroxyethyl starch 6% compared to normal saline are similar to prevent hypotension during spinal anesthesia for cesarean delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevention of Hypotension During Spinal Anesthesia for Caesarean Section: Preload with Crystalloids or Hydroxyethyl Starch

Prevention of hypotension during spinal anesthesia for cesarean section avoids maternal and fetal side effects. The aim of this study is to compare the effects of prehydration with crystalloid and prehydration with Hydroxyethyl starch on maternal blood pressure and neonatal outcome during cesarean section under spinal anesthesia. We enrolled 72 full term women weighting between 50 and 85 Kg, cl...

متن کامل

Effect of crystalloid and colloid preloading on uteroplacental and maternal haemodynamic state during spinal anaesthesia for caesarean section.

We have studied the effects of crystalloid 1 litre (lactated Ringer's) or colloid 0.5 litre (hydroxyethyl starch) preloading in 26 healthy parturients undergoing elective Caesarean section under spinal anaesthesia. Maternal placental uterine artery circulation was measured using a pulsed colour Doppler technique with simultaneous measurement of maternal haemodynamics. A high incidence of matern...

متن کامل

Comparison of Hydroxyethyl Starch 6% and Crystalloids for Preloading in Elective Caesarean Section Under Spinal Anesthesia

BACKGROUND Although controversial, many studies have shown effectiveness of colloid loading as a substitute for crystalloids on reducing the incidence of hypotension in spinal anesthesia. This study was conducted to compare the effects of three intravenous fluid regimens on hemodynamic changes following spinal anesthesia in cesarean section. The regimens included 6% Hydroxyethylstarch 130/0.4 (...

متن کامل

مقایسه اثر هیدروکسی اتیل استارچ با کریستالوئیدها بر تغییرات همودینامیک

Aims and Background: Although controversial, many studies have shown effectiveness of colloid loading as a substitute for crystalloids on reducing the incidence of hypotension in spinal anesthesia. This study was conducted to compare the effects of three intravenous fluid regimens on hemodynamic changes following spinal anesthesia in cesarean section. The regimens included 6% Hydroxy ethyl star...

متن کامل

Crystalloid and colloid preload for maintaining cardiac output in elderly patients undergoing total hip replacement under spinal anesthesia

The aim of the present study was to compare the effects of colloid and crystalloid preload on cardiac output (CO) and incidence of hypotension in elderly patients under spinal anesthesia (SA). A randomized, double-blinded study was conducted including 47 elderly patients undergoing scheduled total hip replacement (THR), who were randomized to three groups: the control group (C group, n = 15), c...