Dimensional Analysis of UVGI Air Disinfection Systems

نویسندگان

  • W. J. Kowalski
  • W. P. Bahnfleth
  • J. L. Rosenberger
چکیده

A dimensional analysis of an ultraviolet germicidal irradiation (UVGI) air disinfection system within a diffusely reflective enclosure is performed using the Buckingham pi theorem. The eight dimensionless parameters obtained include the duct aspect ratio, the lamp aspect ratio, the reflectivity, and terms that incorporate the UV dose, airflow, duct dimensions, and lamp location coordinates. Computer simulation of the dose absorbed by an airborne microbe is used to predict system performance for several thousand combinations of the dimensionless parameters. Statistical analysis of these results is performed to determine the significance of each of the dimensionless parameters and their interactions. Conclusions regarding performance are summarized. The most significant parameters that determine performance of diffusively reflective UVGI systems are shown to be the dose, the reflectivity, the duct geometry, the lamp aspect ratio, lamp location, and various combined functions of these parameters. Practical implications of this research may include the improvement or optimization of UVGI air disinfection systems for in-duct and recirculation unit applications, with a consequent improvement in energy efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UVGI Design Basics for Air and Surface Disinfection

Lethal to microorganisms, ultraviolet radiation in the range of 2250 to 3020 angstroms is used in a variety of disinfection applications, a process referred to as ultraviolet germicidal irradiation (UVGI). Since the first UVGI system was successfully implemented for disinfecting the municipal water system in Marseilles, France, in 1909, the disinfection of medical equipment using UVGI has been ...

متن کامل

Applications of ultraviolet germicidal irradiation disinfection in health care facilities: effective adjunct, but not stand-alone technology.

This review evaluates the applicability and relative contribution of ultraviolet germicidal irradiation (UVGI) to disinfection of air in health care facilities. A section addressing the use of UVGI for environmental surfaces is also included. The germicidal susceptibility of biologic agents is addressed, but with emphasis on application in health care facilities. The balance of scientific evide...

متن کامل

Effects of installation location on performance and economics of in-duct ultraviolet germicidal irradiation systems for air disinfection

In-duct ultraviolet germicidal irradiation (UVGI) systems treat moving air streams in heating, ventilation, and air-conditioning (HVAC) systems to inactivate airborne microorganisms. UVGI system performance and costs to implement and operate the system depend greatly on the output of the UV lamps and the exposure time, which are affected by the temperature and the velocity of the air passing th...

متن کامل

The application of ultraviolet germicidal irradiation to control transmission of airborne disease: bioterrorism countermeasure.

Bioterrorism is an area of increasing public health concern. The intent of this article is to review the air cleansing technologies available to protect building occupants from the intentional release of bioterror agents into congregate spaces (such as offices, schools, auditoriums, and transportation centers), as well as through outside air intakes and by way of recirculation air ducts. Curren...

متن کامل

Ambulance disinfection using Ultraviolet Germicidal Irradiation (UVGI): Effects of fixture location and surface reflectivity.

Ambulances are frequently contaminated with infectious microorganisms shed by patients during transport that can be transferred to subsequent patients and emergency medical service workers. Manual decontamination is tedious and time-consuming, and persistent contamination is common even after cleaning. Ultraviolet germicidal irradiation (UVGI) has been proposed as a terminal disinfection method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003