Keratorefractive Effect of High Intensity Focused Ultrasound Keratoplasty on Rabbit Eyes

نویسندگان

  • Zhiyu Du
  • Pisong Yan
  • Qiang Luo
  • Dan Zhang
  • Yu Zhang
چکیده

Purpose. To evaluate high intensity focused ultrasound (HIFU) as an innovation and noninvasive technique to correct presbyopia by altering corneal curvature in the rabbit eye. Methods. Eighteen enucleated rabbit eyes were treated with a prototype HIFU keratoplasty. According to the therapy power, these eyes were divided three groups: group 1 (1 W), group 2 (2 W), and group 3 (3 W). The change in corneal power was quantified by a Sirius Scheimpflug camera. Light microscopy (LM) and transmission electron microscopy (TEM) were performed to determine the effect on the corneal stroma. Results. In the treated eyes, the corneal curvature increases from 49.42 ± 0.30 diopters (D) and 48.00 ± 1.95 D before procedure to 51.37 ± 1.11 D and 57.00 ± 1.84 D after HIFU keratoplasty application in groups 1 and 3, respectively. The major axis and minor axis of the focal region got longer when the powers of the HIFU got increased; the difference was statistically significant (p < 0.05). LM and TEM showed HIFU-induced shrinkage of corneal stromal collagen with little disturbance to the underlying epithelium. Conclusions. We have preliminarily exploited HIFU to establish a new technique for correcting presbyopia. HIFU keratoplasty will be a good application prospect for treating presbyopia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of High Intensity Focused Ultrasound Keratoplasty on Rabbit Anterior Segment

Purpose. To evaluate the safety of high-intensity focused ultrasound keratoplasty as a treatment for presbyopia by examining its effect on the rabbit anterior segment. Methods. The right corneas of 36 New Zealand rabbits were treated with HIFU keratoplasty. The animals were sacrificed at 1, 7, 15, 30, 60, and 90 days after operation. Collagen type I, MMP-2, and MMP-9 were evaluated using immuno...

متن کامل

The effects of ultrasonically induced hyperthermia on experimental tumors in the rabbit eye.

Greene's melanomas, implanted in the anterior chamber of 31 eyes of 19 Dutch rabbits, were treated with hyperthermia induced by high intensity focused ultrasound (HIFU). The percentage necrosis 24 hr after treatment (N) as a function of steady-state intratumor temperature (T) could be described with N(T) = -181.5 + 4.7T (P less than 0.05). The most frequent side effect was a local hemorrhagic k...

متن کامل

A microsurgical bifurcation rabbit model to investigate the effect of high-intensity focused ultrasound on aneurysms: a technical note

BACKGROUND Recent clinical studies confirmed the high potential of MR-guided focused ultrasound (MRgFUS) in the field of functional neurosurgery. While its ability for precise thermo-ablation within soft tissue is widely recognized, the impact of high-intensity focused ultrasound (HIFU) on larger vessels is less explored. We used a bifurcation aneurysm model in rabbits to investigate the possib...

متن کامل

Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics

Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...

متن کامل

Destructive effect of HIFU on rabbit embedded endometrial carcinoma tissues and their vascularities

OBJECTIVES To evaluate damage effect of High-intensity focused ultrasound on early stage endometrial cancer tissues and their vascularities. MATERIALS AND METHODS Rabbit endometrial cancer models were established via tumor blocks implantation for a prospective control study. Ultrasonic ablation efficacy was evaluated by pathologic and imaging changes. The target lesions of experimental rabbit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016