Assessment of Internal Contamination with Radioactive Iodine for Radiation Workers Two-case Studies

نویسنده

  • N. E. Khaled
چکیده

For the purpose of occupational radiation protection against ionizing radiation, it is important to assess radiation risks due to any contamination events. Effective dose equivalent and body organs dose of workers exposed to 131 I have been estimated in this work. For this sake, both MONDAL 2.0 software and Visual Monte Carlo-dose calculation (VMC-dc) programs were applied. The cases under consideration are: 1) an overexposure of 131 I to ten radiation workers. This event happened during a maintenance period at a Korean nuclear power plant (NPP) where I-131 has been released to the reactor building from a primary system opening[1]. 2) The second event has been occurred in a chemical laboratory responsible for the production of radio-iodine 131 I. A release of the radioisotope in the laboratory air has lead to over exposure to one of the workers [2]. In both cases measurement of radiation activity took place with the use of different techniques where no measurements or estimation for organ doses were performed meanwhile.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation dose of caregivers could be reduced in thyroid carcinoma patients requiring high dose of radioactive iodine: A case report

Undesired radiation exposure to caregivers is an important problem in radioiodine therapy in thyroid carcinoma patients, especially when patient is non-ambulatory. Special precautions are needed to keep the exposure to caregivers low when higher dose of radioiodine is necessary. Here we present a case-report of a 74-year old male patient with papillary thyroid carcinoma with local invasion and...

متن کامل

Risk assessment for chemical pickling of metals contaminated by radioactive materials.

In recent years, many cases of contamination of metal scraps by unwanted radioactive materials have occurred. Moreover, international organisations are evaluating the possibility to re-use or to recycle metals coming from nuclear power plants. The metal recycling industry has started to worry about radiation exposure of workers that could be in contact with contaminated metals during each manuf...

متن کامل

Personnel internal radiation exposure to iodine-125 in a radioiodination laboratory: Exposure levels and trends

ABSTRACT Background: Monitoring internal exposure of individuals handling significant amounts of iodine-125 (I-125) for iodination is of great importance. These individuals are potentially exposed to external contamination, and internal contamination through inhalation, ingestion and intact skin absorption, to I-125. Considering radiological toxicity of this radionuclide its monitoring in the w...

متن کامل

Assessment of radioactive contamination in water bodies around mine workings using radiation counter

The vulnerability of water bodies to contamination within the neighbourhood of open mine cast environ cannot be overemphasized. Evidence of radioactive trace elements associated with the target minerals in the Plateau State (Nigeria) showed the extent of this vulnerability. In order to address this challenge, the radioactivity levels of water samples from mine ponds, streams, wells, and borehol...

متن کامل

Development of RadRob15, A Robot for Detecting Radioactive Contamination in Nuclear Medicine Departments

Accidental or intentional release of radioactive materials into the living or working environment may cause radioactive contamination. In nuclear medicine departments, radioactive contamination is usually due to radionuclides which emit high energy gamma photons and particles. These radionuclides have a broad range of energies and penetration capabilities. Rapid detection of radioactive contami...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012