Anterior chamber flare after femtosecond laser-assisted cataract surgery.
نویسندگان
چکیده
PURPOSE To determine whether postoperative ocular inflammation is less after femtosecond laser-assisted cataract surgery than after conventional phacoemulsification (manual) cataract surgery. SETTING Private clinic, Launceston, Tasmania, Australia. DESIGN Prospective consecutive investigator-masked nonrandomized parallel cohort study. METHODS Consecutive cataract patients who had femtosecond laser-assisted cataract surgery or manual cataract surgery by the same surgeon at a single center were assessed. The primary endpoint was postoperative aqueous flare measured by laser flare photometry at 1 day and 4 weeks. Secondary endpoints included retinal thickness measured by optical coherence tomography and slitlamp examination findings at 4 weeks. RESULTS The per-protocol population comprised 176 patients (100 in laser group; 76 in manual group). Postoperative aqueous flare was significantly greater in the manual cataract surgery group at 1 day (P=.0089) and at 4 weeks (P=.003). There was a significant correlation between effective phacoemulsification time and 1-day postoperative aqueous flare (r = 0.35, P<.0001). The increase in outer zone thickness measured by optical coherence tomography was less in the laser group (P=.007). CONCLUSION Anterior segment inflammation was less after femtosecond laser-assisted cataract surgery than after manual cataract surgery, and this appeared to be due to a reduction in phacoemulsification energy.
منابع مشابه
Femtosecond laser-assisted cataract surgery in vitrectomized eye with posterior chamber phakic intraocular lens.
We describe a case of femtosecond laser-assisted cataract surgery (FLACS) in an eye with multiple comorbidities, including retinal detachment surgery, high myopia, posterior chamber phakic intraocular lens (PC pIOL) and residual, emulsified, silicone oil located in the anterior chamber. FLACS was affected by the optical blockage, but the incomplete capsular tear was recoverable. The case sugges...
متن کاملFemtosecond laser-assisted cataract surgery in a patient with posterior chamber phakic intraocular lens
We describe a case of modified femtosecond laser settings for cataract extraction in a patient with a posterior chamber phakic intraocular lens (PIOL), to avoid incomplete treatment patterns and treatment displacement. Modification of laser settings (increased depth for the capsulotomy, increased vertical spot spacing for the capsulotomy and increased anterior and posterior capsule safety margi...
متن کاملAnterior chamber flare after trabeculectomy and after phacoemulsification.
AIMS To evaluate and compare prospectively the anterior chamber inflammatory response after phacoemulsification cataract surgery and after trabeculectomy with peripheral iridectomy. METHODS Anterior chamber inflammation was measured using the Kowa FM-500 laser flare meter in 131 patients undergoing trabeculectomy and 148 patients undergoing phacoemulsification cataract extraction with intraoc...
متن کاملSuprachoroidal hemorrhage during femtosecond laser assisted cataract surgery
Purpose To describe a case of suprachoroidal hemorrhage that occurred during femtosecond laser assisted cataract surgery (FLACS). Observations A 67-year-old woman with high myopia underwent FLACS. Following two unsuccessful attempts at docking due to interface air bubbles, the third attempt was successful. Laser treatment and cataract surgery proceeded uneventfully until intraocular lens (IOL...
متن کاملFemtosecond laser-assisted cataract surgery in anterior lenticonus due to Alport syndrome
Purpose We describe a case of bilateral anterior lenticonus in a patient with Alport syndrome treated with femtosecond laser-assisted cataract surgery (FLACS). Observations FLACS was performed without complication, and a desirable postoperative visual acuity was achieved. Conclusions and importance Femtosecond laser-assisted cataract surgery is an effective approach for managing patients wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 39 9 شماره
صفحات -