Optimal parameters of electrical impulses for defibrillation by condenser discharges.

نویسنده

  • B Peleska
چکیده

• Determination of the defibrillation threshold of the heart is important not only for developing the technique of defibrillation per se but also for improving the design of instruments used for that purpose. Previous workhas shown the necessity of selecting, for the discharge circuit, parameters that will keep voltage as low as possible, but many questions concerning the optimal parameters for d-c condenser discharges still remain unanswered. Gurvic has described a major portion of existing information on this subject, and Mackay and Leeds have studied optimal parameters for condenser discharges up to 15 microfarads (/AF). However, none of the work reported thus far has utilized a wide enough range of capacitances; the actual voltage at the electrodes was not measured; and inductive effects in the discharge circuit were not taken into account. The present paper reports results based on more than 1000 measurements of defibrillation threshold, together with statistical evaluation of effects obtained by means of three different types of condenser discharge. In all experiments we measured the voltage at the condenser, the voltage at the electrodes, and the current and duration of the discharge impulse. In order to exclude the influence of ischemia" and other technical artefacts, the experiments were done under standard conditions and for this reason the results are valid only for the given technique. Defibrillation thresholds were determined for three types of discharge: 1) pure condenser discharge, as used most frequently in the literature but with very variable results; 2) condenser discharge through an

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac Arrhythmias following Condenser Discharges and Their Dependence upon Strength of Current and Phase of Cardiac Cycle.

• The effect of electric currents upon cardiac activity has attracted increasing interest in connection with electrical defibrillation of the heart. In many cases resuscitation depends largely upon cardiac massage and ventricular defibrillation, whether the chest is open or closed." Although defibrillation of the exposed heart has been adequately studied theoretically as well as practically" th...

متن کامل

Cardiac Arrhythmias following Condenser Discharges Led through an Inductance: Comparison with Effects of Pure Condenser Discharges.

• Transthoracic defibrillaton of the heart can be accomplished by several types of electric impulses, but more information is needed concerning the most suitable voltage and wave form for such impulses. In an earlier study reported in this journal, we described a method of applying graded condenser discharges during selected phases of the cardiac cycle through the intact chest walls of dogs und...

متن کامل

DEFIBRILLATION DOSES/Tacker and Ewy

a markedly overweight patient. Circulation 57: 827, 1978 34. Anderson GJ, Suelzer J: The efficacy of trapezoidal wave forms for ventricular defibrillation. Chest 70: 298, 1976 35. Tacker WA Jr, GuinA GA, Geddes LA, Bourland JD, Korompai FL, Rubio PA: The electrical dose for direct ventricular defibrillation in man. J Thorac Cardiovasc Surg 75: 224, 1978 36. Ewy GA: Subject dependent factors in ...

متن کامل

Effects of hyperbaric oxygenation on coronary artery occlusion in pigs.

No. 1 Some Effects of a Cardioactive Fraction Isolated from Human Blood Plasma on the Peripheral Circulation of the Dog. Winifred C. Nayler, David Race, Jocelyn M. Price, and Thomas E. Lowe 1 Optimal Parameters of Electrical Impulses for Defibrillation by Condenser Discharges. Bohumil Peleska 10 Fibrillation Threshold of Premature Ventricular Responses. Jaok Han, P. D. Garcia de Jalon, and Gord...

متن کامل

Secrecy of Communications in Data Transmission by Impulses with Unknown Moments of Appearance and Disappearance

We carried out a comparative analysis of the algorithms for detecting a rectangular impulse against Gaussian white noise under either authorized or unauthorized access to the transmitted data. We presupposed that for data transmission the binary communication system is used and that the useful information in the data is whether the signal is present or absent. The case is that unauthorized acce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 1966