Risk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study.
نویسندگان
چکیده
PURPOSE To identify risk factors for tendon attrition after volar locking plate fixation of distal radius fractures. METHODS We prospectively assessed attrition of the flexor pollicis longus tendon at volar plate removal in 127 hands in 126 patients. We also evaluated preoperative lateral wrist radiographs, sonographs, and crepitus with flexor pollicis longus tendon motion and compared the demographic and radiographic characteristics of patients with and without tendon attrition. Multivariate logistic regression analysis was employed to identify the factors independently associated with tendon attrition. RESULTS We found 12 cases of tendon attrition (10%) and 1 that presented with tendon rupture in our cohort. Crepitus was recognized in 14 patients (11%): 6 cases (50%) were among the 12 hands in 12 patients with tendon attrition whereas 8 (7%) were detected in the remaining 114 hands in 113 patients. Logistic regression examination revealed that audible crepitus and volar placement of the plate in lateral radiographs were independent predictors of tendon attrition. CONCLUSIONS Crepitus and volar placement of hardware in lateral radiographs were independent risk factors for flexor tendon attrition after volar plating for distal radius fracture. These results may facilitate surgical decisions regarding early plate removal to prevent possible tendon rupture. TYPE OF STUDY/LEVEL OF EVIDENCE Diagnostic II.
منابع مشابه
Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures
Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...
متن کاملAnterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture o...
متن کاملVolar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.
Volar locking plate (VLP) fixation has become the standard surgical treatment for distal radius fractures. However, flexor tendon rupture is one of the major complications following volar plating. This detailed review on the anatomy and morphology of the volar distal radius might facilitate appropriate placement of the volar plate and thereby avoid flexor tendon rupture. We introduce safe and s...
متن کاملTreatment of unstable distal radius fractures with the volar locking plate
BACKGROUND Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures. PURPOSE To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate. PATIENTS AND METHODS A retrospective review was conducted of patients from one instituti...
متن کاملStainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial
BACKGROUND Distal radius fractures are among the most common fractures seen in the hospital emergency department. Of these, over 40% are considered unstable and require some form of fixation. In recent years with the advent of low profile plating, open reduction and internal fixation (ORIF) using volar plates has become the surgical treatment of choice in many hospitals. However, it is currentl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of hand surgery
دوره 40 8 شماره
صفحات -
تاریخ انتشار 2015