Optimization of Gradient Moment Nulling for Hybrid of Opposite-contrast Mra Sequence

نویسندگان

  • T. Kimura
  • M. Ikedo
چکیده

Introduction To enhance slower arterial flow as well as faster flow without increasing imaging time, we have proposed a new MRA technique named hybrid of opposite-contrast MRA (HOP-MRA) that combined standard TOF white-blood (WB) MRA with the flow-sensitive black-blood (FSBB) sequence, resulting in excellent visualization of slow-flow vessels, as compared to the MTC-TOF MRA technique [1,2]. However, flow-void artifacts were notable especially in major brain arteries in the HOP-MRA technique. This was hypothesized to be due to the difference of gradient moment nulling (GMN) in the 1 echo (TOF) part of the sequence. “Phase-encode displacement (PED) artifacts” [3] are well known, in which blood vessels are shifted from the original position depending on velocity, angle between flow and read-out, and gradient shape in a spin warp GRE-based sequence. A full-velocity compensation (3-axis GMN) was employed in the TOF part of the HOP-MRA sequence to reduce the PED artifacts. A standard MTCTOF sequence employed the GMN in k-space center in the two phase-encode directions (2-axis GMN). The purpose of this study was to assess flowvoid artifacts and the degree of PED artifacts due to the GMN difference in TOF part in HOP-MRA. Methods Simulation for the PED artifacts was performed based on Nishimura’s method [3]. Simulation conditions were: time interval between center of phase-encode pulse and the echo peak (deltaT) was 2.85ms, radius (R) of blood-vessel was 3mm and the flowing direction was 45deg that provides a maximum displacement from the read-out direction (X) (Fig. 1a). Imaging was performed on a 1.5-T whole-body imager (EXCELART Vantage, Toshiba Medical Systems Corp.). Dual-echo 3D-gradient-echo sequence (FE3D) and parallel imaging with a reduction factor of 2 were employed. In the 1st echo for TOF, TE=6.4 ms and 1 order GMN was employed. In the 2nd echo (for FSBB), TE=24 ms and flow dephasing gradient of b=2 s/mm were employed. Volume images for HOP-MRA were obtained by simple-weighted subtraction using TOF signal, STOF and FSBB signal, SBB as SHOP=STOF-a*SBB and the scaling coefficient a=1.5 was used. Maximum intensity projection (MIP) was performed without volume selection. Two types of TOF with 3-axis GMN and 2-axis GMN for generating HOP-MRA were compared in simulation and in a volunteer study. Results and Discussion Simulation results showed that vessel walls remained within the ideal vessel positions at velocities below 50 cm/s, though the distortions of vessel profiles were pronounced in higher velocities (Fig. 1b). Flow void artifacts in the HOP-MRA using TOF with 3axis-GMN were decreased by using TOF with 2-axis GMN (Fig. 2). This was likely due to dephasing effects induced by higher order moments over 2 order. Vessel shift artifacts were pronounced in the TOF-MRA with 2-axis GMN but the vessel width remained within the original vessel walls similar to the results of the simulation. Those artifacts, however, were decreased in the HOP-MRA even with the 2-axis GMN due to the contribution of FSBB signal, and the width between vessel walls in the HOP-MRA was almost similar to that with the 3-axis GMN and FSBB where realistic profiles were probably provided. (Fig. 3). Considering less flow-void artifacts and minor vessel shift artifacts, 2-axis GMN is better for the TOF part on HOP-MRA sequence. The HOP technique is suitable for decreasing both flow-void and PED artifacts in MRA compared to TOF alone. References [1] Kimura T et al. MRM62: 450-458 (2009). [2] Kodama T. at al.: Proc of ISMRM, p3416, 2008. [3] Nishimura et al. MRM 22, 481-492, 1991.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid of opposite-contrast MR angiography (HOP-MRA) combining time-of-flight and flow-sensitive black-blood contrasts.

For the purpose of visualizing low-flow as well as high-flow blood vessels without using contrast agents, we propose a new technique called a hybrid of opposite-contrast MR angiography (HOP-MRA). HOP-MRA is a combination of standard time-of-flight (TOF) using a full first-order velocity-compensation for white-blood (WB) and flow-sensitive black-blood (FSBB) techniques, which use motion-probing ...

متن کامل

Phase-enhancement Technique for a Hybrid-of-opposite-contrast Mr Angiography

Introduction: A Flow-sensitive black-blood (FSBB) technique employing to 3D gradient echo (GRE) with motion-probing-gradient [1], and a MRA technique named Hybrid-of-opposite-contrast (HOP) MR angiography combining TOF and FSBB using dual-echo 3DGRE [2] were proposed. In addition, basic idea for correcting wraparound signal in vessels using phase-corrected real signal in FSBB was also proposed ...

متن کامل

بهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا

Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimizatio...

متن کامل

A Note on the Descent Property Theorem for the Hybrid Conjugate Gradient Algorithm CCOMB Proposed by Andrei

In [1] (Hybrid Conjugate Gradient Algorithm for Unconstrained Optimization J. Optimization. Theory Appl. 141 (2009) 249 - 264), an efficient hybrid conjugate gradient algorithm, the CCOMB algorithm is proposed for solving unconstrained optimization problems. However, the proof of Theorem 2.1 in [1] is incorrect due to an erroneous inequality which used to indicate the descent property for the s...

متن کامل

On the hybrid conjugate gradient method for solving fuzzy optimization problem

In this paper we consider a constrained optimization problem where the objectives are fuzzy functions (fuzzy-valued functions). Fuzzy constrained Optimization (FO) problem plays an important role in many fields, including mathematics, engineering, statistics and so on. In the other side, in the real situations, it is important to know how may obtain its numerical solution of a given interesting...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009