Application of Model Free Adaptive Control in Main Steam Temperature System of Thermal Power Plant

نویسنده

  • Lillie Dewan
چکیده

At present, the cascade PID control is widely used to control the superheating temperature (main steam temperature). As Main Steam Temperature has the characteristics of large inertia, large time-delay and time varying, etc., conventional PID control strategy cannot achieve good control performance. In order to overcome the bad performance and deficiencies of main steam temperature control system, Model Free Adaptive Control (MFAC) P cascade control system is proposed in this paper. By substituting MFAC in PID of the main control loop of the main steam temperature control, it can overcome time delays, non-linearity, disturbance and time variation. Keywords—Model free Adaptive Control, Cascade Control, Adaptive Control, PID.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proposed Feature Selection for Dynamic Thermal Management in Multicore Systems

Increasing the number of cores in order to the demand of more computing power has led to increasing the processor temperature of a multi-core system. One of the main approaches for reducing temperature is the dynamic thermal management techniques. These methods divided into two classes, reactive and proactive. Proactive methods manage the processor temperature, by forecasting the temperature be...

متن کامل

Thermodynamic Assessment and Parametric Study of a Supercritical Thermal Power Plant

A thermodynamic analysis of an operational 315 MW supercritical steam power plant (SPP) using the actual data is performed to assess the plant performance and identify the sites of energy losses and exergy destructions in each component of the plant. Various performance parameters such as component energy and exergy efficiencies, energy loss rate, exergy destruction rate, improvement potential ...

متن کامل

Boiler Modelling and Optimal Control of Steam Temperature in Thermal Power Plants

Achieving accurate control of main steam temperature is a very difficult task in thermal power plants due to the large process lag (8 to 10 minutes) associated with the superheater system and there exists a deviation of ± 10 °C in closed loop control. A control oriented boiler model and an appropriate optimal control strategy are the essential tools for improving the accuracy of this control sy...

متن کامل

Conceptual design of a super-critical CO2 brayton cycle based on stack waste heat recovery for shazand power plant in Iran

Conceptual design of a waste heat recovery cycle is carried out in attempt to enhance the thermal efficiency of a steam power plant. In the recovery system, super-critical an CO2 is employed as the working fluid operating in a Brayton cycle. Low grade heat rejected by the flue gases through the stack is used as the primary heat source, while a secondary heat exchanger utilizes th...

متن کامل

A System Dynamics Model to Evaluate Emissions in A Combined Cycle Power Plant

Environment and the need to protect and care for it, is one of the main concerns of industrial development in todaychr('39')s society; and air pollution is one of the most noticeable and tangible causes of it. The increasingly growth of the industry has led to the production and diffusion of gaseous pollutants into the air and among them; thermal power plants are one of the most important sourc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015