Water content of ampoule packaged with ProRoot MTA.

نویسندگان

  • M H Nekoofar
  • D C Haddad
  • J Nolde
  • Z Aseeley
چکیده

We are writing to draw attention to an inconsistency in the amount of water in the packages of both white and grey MTA which are commercially available as ProRoot MTA Original (Dentsply International Inc., Johnson City, TN, USA) and ProRoot MTA (Dentsply International Inc.). In each package, there are five sachets (pouches) containing 1 g of ProRoot MTA powder and six ampoules of water. The manufacturer claims that the amount of water inside each ampoule is equal to 0.35 g. This information is written on the sides of each package. However, unfortunately, we have determined that the amounts of water in the ampoules are inconsistent. Our first reaction to this finding was to recheck the accuracy of our measurements. The accuracy of the laboratory digital scale was confirmed by using predetermined standard weights. Afterwards, in an attempt to evaluate the amount of water in each ampoule; 58 ampoules from various packages of ProRoot MTA original (grey) and ProRoot MTA (white) were chosen randomly. The samples were kept at a controlled laboratory temperature (20 C) for 24 h before measurement. The weight of each ampoule with the water inside was measured using a Precisa 80A-200M device (Zürich, Switzerland), an analytical laboratory balance that measures weight to a high degree of accuracy. The analytical balance was stabilized at zero then the weight of each ampoule with the water inside was measured and recorded to an accuracy of three decimal places at 20 C. Then the tip of each ampoule was removed using a surgical scalpel and water was released carefully into a glass container, which had also been kept at 20 C for 24 h. Then, the weight of water was measured (MW) to an accuracy of three decimal places at 20 C. Subsequently the weight of each empty plastic container and the removed tip section were also determined. To calculate the definitive amount of water inside the ampoules, the weight of each empty plastic container and the cut tip were subtracted from the weight of ampoules before opening. The value obtained was considered as the definitive amount of water inside each ampoule (DW). The mean difference of the definitive water (DW) and measured water (MW) was 0.011 g (range: ‘0.30 g, 0.000 g’ with a SD: 0.007). This is the amount of water that could not be released from the plastic ampoule. However, in the clinical situation this amount of water would probably remain in the ampoules. Both the definitive and measured values were compared with the amount of water that the manufacturer claims is inside the ampoules. The results are demonstrated in Figs 1 and 2. The average measured (MW) and definitive weight (DW) of water in the ampoules were 0.211 g (range: ‘0.140 g, 0.270 g’; SD: 0.40) and 0.223 g (range: ‘0.149 g, 0.290 g’; SD: 0.40) respectively. These values are 0.139 g (range: ‘0.210 g, 0.800 g’) and 0.198 g (range: ‘0.201 g, 0.060 g’) less than the amount of water claimed to be inside the ampoules. This lack of consistency in the amount of water inside ProRoot MTA packages is of concern and may explain the uncontrolled and undesirable characteristics of the material in certain clinical and laboratory situations. MTA consists of hydraulic powders that set and harden in the presence of water through the hydration process. According to the US patent number 5 415 547, the principle component of MTA is Portland cement (Torabinejad & Dean 1995). Complete hydration of Portland cement cannot occur if the water/cement ratio is below a certain value (Taylor 1997). The ratio of 0.33 is recommended for MTA (Fridland & Rosado 2003) and this is reflected in the nominal 0.35 g of water that is provided alongside each 1 g of MTA powder by the manufacturer. In the manufacturer’s instructions for use, which can be found inside the package, it is also clearly stated that: ‘Note: 1: Adding too much, or too little liquid will reduce the ultimate strength of the material.’ The setting of Portland cement and thus MTA takes place in two stages. After mixing with water the hydration reaction of calcium silicates begins and results in the formation of a gel consisting of calcium silicate hydrates, which liberates calcium hydroxide. The calcium hydroxide then gradually reacts with the minerals to form other hydrated compounds. The doi:10.1111/j.1365-2591.2009.01541.x

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro study of different material properties of Biodentine compared to ProRoot MTA

INTRODUCTION The aim of this study was to compare solubility, microhardness, radiopacity, and setting time of Biodentine with ProRoot MTA. METHODS Solubility in distilled water, radioopacity, and setting time were evaluated in accordance with International Standard ISO 6876:2001. In addition, the solubility in Phosphate Buffered Saline (PBS) buffer was determined. For microhardness-testing, t...

متن کامل

Effect of ProRoot MTA mixed with chlorhexidine on apoptosis and cell cycle of fibroblasts and macrophages in vitro.

AIM To compare the percentage of apoptotic cells and the cell cycle profile of fibroblasts and macrophages exposed to either ProRoot mineral trioxide aggregate (MTA) mixed with chlorhexidine (CHX), or exposed to ProRoot MTA mixed with sterile water. METHODOLOGY Mouse gingival fibroblasts or mouse macrophages were seeded in six-well plates and allowed to attach overnight. Freshly mixed or set ...

متن کامل

Ion release, porosity, solubility, and bioactivity of MTA Plus tricalcium silicate.

INTRODUCTION The aim of this study was to evaluate MTA Plus (Prevest Denpro Limited, Jammu, India, for Avalon Biomed Inc) material's properties, namely calcium release, the pH change, solubility, water sorption, porosity, surface morphology, and apatite-forming ability after immersion in simulated body fluid. METHODS Two tricalcium silicate powders (MTA Plus and ProRoot MTA; Dentsply Tulsa Sp...

متن کامل

Comparative study of physico-chemical properties of MTA-based and Portland cements.

The purpose of this investigation was to evaluate the physicochemical properties of gray and white structural and nonstructural Portland cement, gray and white ProRoot MTA and MTA BIO. The water/powder ratio, setting time, solubility and pH (hydrogen-ion potential) changes of the materials were evaluated. Tests followed specification #57 from the American National Standard Institute/American De...

متن کامل

Superfast Set, Strong and Less Degradable Mineral Trioxide Aggregate Cement

Purpose Despite the good sealing ability and biocompatibility of mineral trioxide aggregate (MTA), its slow setting, high degradation, and weakness limit its use in surgical endodontics and high stress-bearing areas. This study aimed to develop two new liquids to control these drawbacks. They were prepared from calcium chloride, fumed silica, and hydroxyapatite or calcium phosphate and coded "H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 42 6  شماره 

صفحات  -

تاریخ انتشار 2009