Electric block current induced detachment from surgical stainless steel and decreased viability of Staphylococcus epidermidis.

نویسندگان

  • A J van der Borden
  • H C van der Mei
  • H J Busscher
چکیده

In vitro studies investigating the influence of electric DC current on bacterial detachment have demonstrated that continuous currents of only 25-125 microA stimulated staphylococcal strains to detach from surgical stainless steel. However, DC currents produce more power that has to be dissipated by the skin as compared to alternating currents. Also, an excess of ions on the steel can cause negative osteogenesis and fixation results. Therefore, it is the aim of this paper to examine whether detachment of Staphylococcus epidermidis from stainless steel surfaces in a parallel plate flow chamber can also be stimulated using electric block currents. Block currents of 15, 60 and 100 microA with different frequencies (0.1-2 Hz) and duty cycles (5-50%) were applied to induce bacterial detachment. Block currents of 100 microA cause detachment of about 76% of adhering staphylococci from stainless steel, whereas in addition the remaining bacteria are less viable, as determined by culturing the remaining bacteria on agar plates. Therewith, block current-induced detachment of adhering bacteria from stainless steel appears to be an equally promising method to prevent infection of orthopaedic fixation pins and screws than application of DC currents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electric-current-induced detachment of Staphylococcus epidermidis strains from surgical stainless steel.

Infection of percutaneous biomaterials implants, such as fixation frames used for the repair of complicated fractures in orthopedics, is a major complication that almost inevitably leads to replacement of the implant. As antibiotic therapy usually has little impact on biomaterial-associated infections, it is the aim of this article to examine whether implant-associated Staphylococcus epidermidi...

متن کامل

Biofilm-Forming Staphylococcus epidermidis Expressing Vancomycin Resistance Early after Adhesion to a Metal Surface

We investigated biofilm formation and time of vancomycin (VCM) resistance expression after adhesion to a metal surface in Staphylococcus epidermidis. Biofilm-forming Staphylococcus epidermidis with a VCM MIC of 1 μg/mL was used. The bacteria were made to adhere to a stainless steel washer and treated with VCM at different times and concentrations. VCM was administered 0, 2, 4, and 8 hours after...

متن کامل

Factors Affecting Adhesion of Staphylococcus epidermidis to Stainless Steel Surface

In the food industry, microbial adhesion to equipment surfaces and subsequent development of biofilm are very serious issues because of potential to cause cross-contamination, which leads to lowered shelf-life, food spoilage, and transmission of disease [1-4]. Adhesion and subsequent growth on surfaces is a common strategy of bacteria for survival in both natural habitats and man-made environme...

متن کامل

Cinnamon Oil and Chitosan Coating on Orthopaedic Implant Surface for Prevention of Staphylococcus Epidermidis Biofilm Formation.

S. Epidermidis is among the most frequently isolated microorganisms found in -infection related to implanted devices and the formation of biofilm will be more resistant compared to the planktonic form. This study was carried out to determine the effect of coating on stainless steel orthopaedic implants surfaces with cinnamon oil and chitosan as bioadhesive to prevent biofilms formation of S. Ep...

متن کامل

Adherence ability of Staphylococcus epidermidis on prosthetic biomaterials: an in vitro study

Bacterial adhesion to the surface of biomaterials is an essential step in the pathogenesis of implant-related infections. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis to adhere to the surface of solid biomaterials, including oxidized zirconium-niobium alloy (Oxinium), cobalt-chromium-molybdenum alloy, titanium alloy, commercially pure titanium, and stainless...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 26 33  شماره 

صفحات  -

تاریخ انتشار 2005