The impact of prosthetic design on the stability, marginal bone loss, peri-implant sulcus fluid volume, and nitric oxide metabolism of conventionally loaded endosseous dental implants: a 12-month clinical study.

نویسندگان

  • Tolga F Tözüm
  • Güliz N Güncü
  • Nermin Yamalik
  • Ilser Turkyilmaz
  • M Baris Güncü
چکیده

BACKGROUND Further clarification of the early and late response of peri-implant tissues to surgical insertion and loading of dental implants and the potential associations among the various implant-related measures are likely to improve the evaluation/monitoring of implant sites. Thus, analyses were made of the volume and nitric oxide (NO) profile of peri-implant sulcus fluid (PISF), implant stability, and marginal bone level in relation to different prosthetic designs. METHODS Seven totally edentulous subjects and 11 partially edentulous subjects were included. Resonance frequency analysis (RFA), marginal bone level measurements, PISF volume, and spectrophotometrically determined nitrite levels were analyzed comparatively at conventionally loaded (CL) implant sites and at implants with removable prostheses (RP; N = 14) and fixed prostheses (FP; N = 11) for a period of 12 months. RESULTS At implant sites with RP, PISF volume decreased gradually and its lowest level occurred at the end of the experimental period. The PISF nitrite content increased until 6 months and was followed by a significant decrease at 12 months. Compared to baseline, RFA values exhibited a significant decrease at 1 and 3 months. Marginal bone level was significantly lower at all follow-up visits compared to baseline. More volumetric fluctuations of PISF was noted at implant sites with FP. The PISF nitrite content had decreased, compared to baseline, at 6, 9, and 12 months. A general stability was observed for RFA. The marginal bone loss observed at 6 months was followed by a gain at 12 months. An inverse relationship was noted between RFA values and marginal bone levels. CONCLUSION The prosthetic design particularly seems to affect the NO metabolism around CL implants, whereas it does not seem to have any impact on the stability of dental implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

بررسی رادیوگرافیک اثر بارگذاری تدریجی بر روی تغییرات استخوان کرستال و تراکم استخوان اطراف ایمپلنت‌های تک واحدی خلف ماگزیلا

Background and Aim: The aim of this clinical study was to determine the effectiveness of progressive loading procedures on preserving crestal bone height and improving peri-implant bone density around maxillary implants restored with single crowns by an accurate longitudinal radiographic assessment technique. Materials and Methods: Eleven Micro-Thread Osseo Speed dental implants were place...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Adipose- Derived Stem Cells as a Tool for Dental Implant Osseointegration: an Experimental Study in the Dog

The biological interaction between the jaw bones and dental implant is fundamental for the long-term success of dental implant placement. Nevertheless, the insufficient bone volume remains a major clinical problem, especially in case of immediate dental implant. Using a canine model, the present study proves the regenerative potential of adipose- derived stem cells (ADSCs) to repair peri-implan...

متن کامل

Receptor Activator of Nuclear Factor Kappa B Ligand (RANKL) Levels in Peri-Implant Crevicular Fluid

Background: Receptor activator of nuclear factor kappa B ligand (RANKL) is one of the key cytokines in the induction of osteoclastogenesis both in vitro and in vivo.Several reports indicated the presence of sRANKL in gingival crevicular fluid of patients with periodontal diseases. Objective: To determine the presence of RANKL in peri-implant crevicular fluid samples of implants with peri-implan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of periodontology

دوره 79 1  شماره 

صفحات  -

تاریخ انتشار 2008