[Post-lasik corneal ectasia in patients with significant differences in keratometry readings between both eyes].

نویسندگان

  • J Ortega-Usobiaga
  • F Llovet-Osuna
  • M R Djodeyre
  • A Llovet-Rausell
  • J Beltran-Sanz
  • J Baviera-Sabater
چکیده

OBJECTIVES A study is made on the incidence of corneal ectasia after laser in situ keratomileusis (LASIK) in patients with large differences in mean keratometry (MK) readings between both eyes (OU). Visual outcomes were also evaluated. METHODS The medical records of 164,603 patients (315,259 eyes) who underwent LASIK from January 2003 to December 2011 were reviewed in order to identify patients with a difference in MK of ≥ 1.25 D between OU. The main outcome measures were incidence of ectasia after LASIK, and visual outcome. RESULTS A total of 35 eyes that met the inclusion criteria were found. Functional and visual results were those expected for myopia studies. After a minimum follow-up of 2 years, no corneal ectasia was found in 3 eyes (2 patients). CONCLUSIONS The possibility of finding a patient with an asymmetry in MK and normal topography is low (0.021%), and it does not seem to be a contraindication of LASIK. Although no corneal ectasia was found in this case series, and as it is a potentially sight-threatening complication, patients with very different MK between OU should be studied carefully before undergoing LASIK.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Modified Risk Assessment Scoring System for Post Laser In Situ Keratomileusis Ectasia in Topographically Normal Patients

PURPOSE To evaluate and modify the Randleman Ectasia Risk Score System for predicting post-laser in situ keratomileusis (LASIK) ectasia in patients with normal preoperative corneal topography. METHODS In this retrospective study we reviewed data from 136 eyes which had undergone LASIK including 34 ectatic and 102 normal eyes between 1999 and 2009. After determining the sensitivity and specifi...

متن کامل

Ectasia following small-incision lenticule extraction (SMILE): a review of the literature

PURPOSE Four cases of corneal ectasia after small-incision lenticule extraction (SMILE) have been reported. In this review, we provide an overview of the published literature on corneal ectasia after SMILE and risk factors associated with this complication. METHODS Case reports were identified by a search of seven electronic databases for pertinent heading terms between 2011 and July 2017. We...

متن کامل

Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients

INTRODUCTION Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasia. The aim of this work was to find out if there is a statistically significant correlation betwee...

متن کامل

Corneal ectasia induced by laser in situ keratomileusis.

PURPOSE To identify factors that can lead to corneal ectasia after laser in situ keratomileusis (LASIK). SETTING University refractive surgery center. METHODS In this retrospective study, the charts of all patients (2873 eyes) who had LASIK between May 1995 and November 1999 were reviewed. Fourteen patients (19 eyes, 0.66%) developed post-LASIK ectasia. The mean follow-up was 16.32 months (...

متن کامل

Repeatability and Reproducibility of Corneal Biometric Measurements Using the Visante Omni and a Rabbit Experimental Model of Post-Surgical Corneal Ectasia.

PURPOSE To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. METHODS Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de la Sociedad Espanola de Oftalmologia

دوره 89 3  شماره 

صفحات  -

تاریخ انتشار 2014