The accuracy of preload assessment by different transesophageal echocardiographic techniques in patients undergoing cardiac surgery.

نویسندگان

  • Christoph K Hofer
  • Michael T Ganter
  • Andreas Rist
  • Richard Klaghofer
  • Sonja Matter-Ensner
  • Andreas Zollinger
چکیده

OBJECTIVES The aim of this study was to compare the following approaches to assess left ventricular preload by transesophageal echocardiography (TEE): left ventricular end-diastolic volume index (LVEDVI) determined by using the method of disc summation (LVEDVI(Md)) and left ventricular end-diastolic area index (LVEDAI) were compared with LVEDVI assessed by the modified Simpson formula (LVEDVI(Si)). Global end-diastolic volume index (GEDVI) and stroke volume index (SVI) measured by the PiCCO(plus) system (Pulsion Medical Systems, Munich, Germany) were used as TEE-independent reference variables. DESIGN Prospective observational study. SETTING Community hospital. PARTICIPANTS Twenty-two patients undergoing elective cardiac surgery. INTERVENTIONS After the induction of anesthesia, hemodynamic assessment by TEE and the PiCCO(plus) system was made 20 (T(1)) and 10 minutes (T(2)) before and 10 (T(3)) and 20 minutes (T(4)) after a fluid trial. At each time point, LVEDVI(Md), LVEDAI, LVEDVI(Si), GEDVI, and SVI were determined. MEASUREMENTS AND MAIN RESULTS The fluid trial resulted in a significant increase of all preload variables measured at T(3). At T(4), all preload variables but LVEDVI(Md) showed a significant decrease. The mean bias +/- 2 SD for percent changes (Delta) of LVEDVI(Md) - DeltaLVEDVI(Si) was 1.5% +/- 59.0% and for DeltaLVEDAI - Delta LVEDVI(Si) 0.9% +/- 23.6%. The correlation between LVEDVI(Md) and LVEDVI(Si) was significantly weaker than between LVEDAI and LVEDVI(Si) (p < 0.001). Comparing TEE measurements with GEDVI and SVI, strong correlations were observed for LVEDAI and LVEDVI(Si) only. CONCLUSION The method of disc summation cannot be recommended for preload assessment during a fluid challenge in cardiac surgery patients. By contrast, single-plane area measurements provided reliable information when compared with the application of the modified Simpson formula.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the immediate effects of cardiopulmonary bypass on left ventricular performance by on-line pressure-area relations.

BACKGROUND Pressure-volume relations have been established as useful measures of left ventricular (LV) performance. Application of these methods to the intraoperative setting have been limited because of difficulties acquiring LV volume data. Transesophageal echocardiographic automated border detection can measure LV cross-sectional area as an index of volume, which can be coupled with pressure...

متن کامل

Impairment of cardiac performance by laparoscopy in patients receiving positive end-expiratory pressure.

BACKGROUND The cardiopulmonary effects of the combination of abdominal and thoracic pressures in humans have not been well delineated. OBJECTIVE To study the cardiopulmonary effects of 15 mm Hg of intra-abdominal pressure in the presence and absence of 10 cm H20 of positive end-expiratory pressure (PEEP). DESIGN Prospective. SETTING University hospital. METHODS Nine patients undergoing ...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study.

STUDY DESIGN Prospective randomized study of patients undergoing spine surgery. OBJECTIVE To compare changes in hemodynamic and cardiac function after prone positioning using different prone positioners. SUMMARY OF BACKGROUND DATA Prone positioning decreases blood pressure and cardiac function. Several studies have evaluated changes in cardiac function after prone positioning, and linked th...

متن کامل

Echocardiographic detection of left atrial mobile calcium debris of trido valve surgery: a case report

Calcification of the cardiac chambers is among the challenges associated with reoperative cardiac surgeries by increasing the risk of systemic embolization. We experienced a case of an unexpected detected mass by intraoperative transesophageal echocardiography during weaning from cardiopulmonary bypass in a patient undergoing trido mitral and tricuspid valve replacement surgery. The surgically ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiothoracic and vascular anesthesia

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2008