Detection of methicillin-resistant Staphylococcus aureus (MRSA) in specimens from various body sites: performance characteristics of the BD GeneOhm MRSA assay, the Xpert MRSA assay, and broth-enriched culture in an area with a low prevalence of MRSA infections.
نویسندگان
چکیده
Universal surveillance upon patient admission is important in reducing the transmission of methicillin-resistant Staphylococcus aureus (MRSA) and associated disease in hospitals. High costs for the health care system in conjunction with MRSA have promoted the development of rapid screening methods to detect MRSA carriers. This study compared two real-time PCR methods, the BD GeneOhm MRSA assay (BDGO) and the Xpert MRSA assay, with broth-enriched culture to define their performance characteristics and rapidity in an area with low MRSA prevalence. In total, 414 swabs from the nose and 389 swabs from the groin from 425 patients were tested. Of those 425 patients, 378 had swabs from both the nose and groin in parallel. Two hundred thirty-one and 194 patients were randomly assigned to the BDGO group and the Xpert MRSA group, respectively. In general, sensitivity, specificity, and negative predictive value (NPV) were high for the BDGO (100%, 98.5%, and 100%, respectively) and the Xpert MRSA (100%, 98.2%, and 100%, respectively), irrespective of whether or not nasal and inguinal specimens were considered alone or combined. In contrast, the positive predictive value (PPV) was lower: before the resolution of discrepant results, the PPVs for nasal and inguinal specimens alone and combined were 87.5%, 86.7%, and 82.4% for the BDGO and 91.7%, 66.7%, and 92.9% for the Xpert MRSA, respectively. After the resolution of discrepant results, PPVs were 93.8%, 93.3% and 94.1% for the BDGO and 91.7%, 88.9% and 92.9% for the Xpert MRSA, respectively. With the BDGO, 4 of 16 carriers were each identified by nasal or inguinal swabs alone, whereas in the Xpert MRSA group, 4 of 13 carriers were exclusively identified by nasal swabs and 2 of 13 were identified by inguinal swabs alone. Both PCR methods showed no significant difference in the number of discrepant results (odds ratio, 0.70 [P = 0.789]), but specimens from wounds and other body sites (axilla, vagina, and throat) produced discrepancies more often than nasal and groin specimens (odds ratios, 4.724 [P = 0.058] and 12.163 [P < 0.001], respectively). The facts that no false-negative PCR results were detected and increased PPVs were found after the resolution of discrepant results point to PCR as the actual gold standard. Since both sensitivity and NPV were exceptionally high for PCR, backup cultures may, therefore, be unnecessary in an area with low prevalence and with a preemptive isolation strategy but may still be useful for PCR-positive specimens because of the lower PPV for both methods and the possibility of susceptibility testing. The median time for analysis, including extraction, hands-on time, and actual PCR was 2 h 20 min for the Xpert MRSA versus 5 h 40 min for the BDGO. Concerning reporting time, including administration and specimen collection, the Xpert MRSA was faster than the BDGO (7 h 50 min versus 17 h).
منابع مشابه
Multicenter evaluation of the Cepheid Xpert methicillin-resistant Staphylococcus aureus (MRSA) test as a rapid screening method for detection of MRSA in nares.
The first U.S. multicenter clinical trial to assess the performance of the Cepheid Xpert MRSA assay (Xpert MRSA) was conducted. The assay is a qualitative test designed for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) directly from nares swabs. This novel test combines integrated nucleic acid extraction and automated real-time PCR for the detection of a MRSA-specifi...
متن کاملComparison of the BD Max methicillin-resistant Staphylococcus aureus (MRSA) assay and the BD GeneOhm MRSA achromopeptidase assay with direct- and enriched-culture techniques using clinical specimens for detection of MRSA.
We evaluated the new, fully automated molecular BD Max methicillin-resistant Staphylococcus aureus (MRSA) assay for detection of methicillin-resistant S. aureus in a low-prevalence (4.1%) setting. Sensitivity, specificity, and positive and negative predictive values were 93.9%, 99.2%, 83.8%, and 99.7%, respectively. The assay reported fewer unresolved results than the BD GeneOhm MRSA ACP assay.
متن کاملComparison of the Xpert methicillin-resistant Staphylococcus aureus (MRSA) assay, BD GeneOhm MRSA assay, and culture for detection of nasal and cutaneous groin colonization by MRSA.
Detection of methicillin (meticillin)-resistant Staphylococcus aureus colonization was assessed using combined nose and groin swabs in two commercial PCR assays (the Xpert MRSA assay and the BD GeneOhm MRSA assay). Compared to routine culture, both had similar sensitivities (87.0% versus 84.8%, respectively) and specificities (93.8% versus 92.7%, respectively). Combined PCR assays provide a rap...
متن کاملEvaluation of the BD GeneOhm MRSA and VanR Assays as a Rapid Screening Tool for Detection of Methicillin-Resistant Staphylococcus aureus and Vancomycin-Resistant Enterococci in a Tertiary Hospital in Saudi Arabia
Objectives. The aim of this study was to evaluate the diagnostic performance of BD GeneOhm VanR Assay, a rapid PCR test that detects the presence of vanA and/or vanB genes and the performance of BDGeneOhm MRSA Assay which detects the staphylococcal cassette chromosomemec (SCCmec cassette) carrying the mecA gene and Staphylococcus aureus specific sequence located within the orfX gene. Methods. 3...
متن کاملComparison of the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR assay to culture by use of BBL CHROMagar MRSA for detection of MRSA in nasal surveillance cultures from an at-risk community population.
We compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR assay to culture with BBL CHROMagar MRSA for nasal surveillance among 602 arrestees from the Baltimore City Jail. The sensitivity and specificity were 88.5% and 91.0%, respectively, and after secondary analysis using enrichment broth, they were 89.0% and 91.7%, respectively. Twenty-three of 42 false-positive PCR l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 48 11 شماره
صفحات -
تاریخ انتشار 2010