Background—The aim of this study was to validate exhaled nitric oxide (eNO) values obtained with an alternative oV line, single breath, low flow balloon sampling method against on line sampling according to ERS and ATS guidelines in children who could perform both methods. Methods—One hundred and twenty seven white children of median age 14.1 years, all pupils of a secondary school, participated in the study. They performed the two diVerent sampling techniques at three diVerent flows of 50, 100, 150 ml/s. Additional measurements were done in random subgroups to determine the influence of the dead space air on eNO values obtained oV line by excluding the first 220 ml of exhaled air. All children completed a questionnaire on respiratory and allergic disorders and underwent spirometric tests. Results—The oV line eNO values were significantly higher than the on line values at all flows. At 50 ml/s the geometric mean (SE) oV line eNO was 18.7 (1.1) ppb and the on line eNO was 15.1 (1.1) ppb (p<0.0001). However, when dead space air was discarded, oV line and on line values were similar: at 50 ml/s oV line eNO was 17.7 (1.0) ppb and on line eNO 16.0 (1.2) ppb. There was a good agreement between oV line eNO values without dead space air and on line eNO: for 50 ml/s the mean on/oV line ratio was 0.95 (95% agreement limits 0.63 to 1.27). The oV line eNO level at 50 ml/s in 80 children with negative questionnaires for asthma, rhinitis, and eczema was 13.6 (1.0) ppb compared with 33.3 (1.1) ppb in the remaining children with positive questionnaires on asthma and allergy and/or recent symptoms of cold (p<0.0001). Conclusions—In children, oV line assessment of eNO using constant low flow sampling and excluding dead space air is feasible and produces similar results as on line assessment with the same exhalation flow rate. Both sampling methods are sufficiently sensitive to diVerentiate between groups of otherwise healthy school children with and without self-reported asthma, allergy, and/or colds. We propose that, for oV line sampling, similar low flow rates should be used as are recommended for on line measurements. (Thorax 2001;56:285–289)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exhaled nitric oxide measurements with dynamic flow restriction in children aged 4-8 yrs.

Fractional exhaled nitric oxide concentration (FENO) depends on exhalation flow; however, children often are unable to perform controlled flow procedures. Therefore, a device was developed for off-line FENO sampling, with dynamic flow restriction (DFR). The authors compared off-line with on-line FENO, assessed feasibility, and obtained normal values for FENO in children aged 4-8 yrs. Subjects i...

متن کامل

Off-line sampling of exhaled air for nitric oxide measurement in children: methodological aspects.

Measurement of nitric oxide in exhaled air is a noninvasive method to assess airway inflammation in asthma. This study was undertaken to establish the reference range of exhaled NO in healthy school-aged children and to determine the influence of ambient NO, noseclip and breath-holding on exhaled NO, using an off-line balloon sampling method. All children attending a primary school (age range 8...

متن کامل

Sampling of exhaled nitric oxide in children: end-expiratory plateau, balloon and tidal breathing methods compared.

The aim of this study was to compare exhaled nitric oxide concentrations obtained during controlled slow exhalation, presently considered as the method of choice, with two sampling methods that are easily performed by children: blowing air into a balloon and tidal breathing through a mouthpiece. One hundred and one well controlled, stable allergic asthmatic children (median age 11.7 yrs) perfor...

متن کامل

[Fractional exhaled nitric oxide in monitoring and therapeutic management of asthma].

INTRODUCTION Asthma is a chronic respiratory disease characterized by hyper-responsiveness and bronchial inflammation. The bronchial inflammation in these patients can be monitored by measuring the fractional exhaled nitric oxide. This study aims to determine fractional exhaled nitric oxide association with peak expiratory flow and with asthma control inferred by the Global Initiative for Asthm...

متن کامل

Comparison of single-breath and tidal breathing exhaled nitric oxide levels in infants.

The aim of this study was to compare two different methods, tidal breathing (TB) and single-breath (SB), for measuring fractional exhaled nitric oxide (FENO) in infants. FENO was measured in 71 infants with either recurrent wheeze (n=32), recurrent cough (n=16) or no symptoms (healthy, n=23) using both methods. For TB measurements five breaths were collected into a gas sampling bag (off-line re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001