Does cerebral blood flow decline in healthy aging? A PET study with partial-volume correction.
نویسندگان
چکیده
UNLABELLED It remains a matter of controversy as to whether cerebral perfusion declines with healthy aging. In vivo imaging with PET permits quantitative evaluation of brain physiology; however, previous PET studies have inconsistently reported aging reductions in cerebral blood flow (CBF), oxygen metabolism, and glucose metabolism. In part, this may be because of a lack of correction for the dilution effect of age-related cerebral volume loss on PET measurements. METHODS CBF PET scans were obtained using [15O]H2O in 27 healthy individuals (age range, 19-76 y) and corrected for partial-volume effects from cerebral atrophy using an MR-based algorithm. RESULTS There was a significant difference (P = 0.01) in mean cortical CBF between young/midlife (age range, 19-46 y; mean +/- SD, 56+/-10 mL/100 mL/min) and elderly (age range, 60-76 y; mean +/- SD, 49+/-2.6 mL/100 mL/min) subgroups before correcting for partial-volume effects. However, this group difference resolved after partial-volume correction (young/midlife: mean +/- SD, 62+/-10 mL/100 mL/min; elderly: mean +/- SD, 61+/-4.8 mL/100 mL/min; P = 0.66). When all subjects were considered, a mild but significant inverse correlation between age and cortical CBF measurements was present in the uncorrected but not the corrected data. CONCLUSION This study suggests that CBF may not decline with age in healthy individuals and that failure to correct for the dilution effect of age-related cerebral atrophy may confound interpretation of previous PET studies that have shown aging reductions in physiologic measurements.
منابع مشابه
Loss of D2 receptor binding with age in rhesus monkeys: importance of correction for differences in striatal size.
The relation between striatal dopamine D2 receptor binding and aging was investigated in rhesus monkeys with PET. Monkeys (n = 18, 39 to 360 months of age) were scanned with 11C-raclopride; binding potential in the striatum was estimated graphically. Because our magnetic resonance imaging analysis revealed a concomitant relation between size of striatum and age, the dynamic positron emission to...
متن کاملMeasurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects.
Accuracy in in vivo quantitation of brain function with positron emission tomography (PET) has often been limited by partial volume effects. This limitation becomes prominent in studies of aging and degenerative brain diseases where partial volume effects vary with different degrees of atrophy. The present study describes how the actual gray matter (GM) tracer concentration can be estimated usi...
متن کامل30: Cerebral Blood Flow and Cerebral Oxygen Metabolism in Normal Aging: a Precursor for Study of Dementia and Alzheimer's Disease
Background and aims: Aging brain has been demonstrated to be the main risk factor for dementia and Alzheimer’s disease (AD). Recent findings provide clear evidence that the structural and functional integrity of the brain depends on the delicate balance between substrate delivery through blood flow and energy demands imposed by neural activity. Imaging studies of aging have in general shown red...
متن کاملAccuracy of a method using short inhalation of (15)O-O(2) for measuring cerebral oxygen extraction fraction with PET in healthy humans.
UNLABELLED PET with short inhalation of (15)O-O(2) provides regional oxygen extraction fraction (OEF) in a shorter acquisition time and with less radiation exposure than does the steady-state method. The purpose of this study was to test the accuracy of the short-inhalation technique for estimating OEF in healthy human volunteers. METHODS The final study population included 16 healthy volunte...
متن کاملEffect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 41 11 شماره
صفحات -
تاریخ انتشار 2000