Duplex sonography in the evaluation of carotid artery disease.
نویسندگان
چکیده
High-resolution duplex sonography was compared with biplane magnified carotid angiography in a prospective evaluation of 161 carotid arteries in 86 patients. The duplex scanner combined real-time B-mode imaging (7.5 MHz) with simultaneous range-gated pulsed Doppler frequency analysis (3 MHz). The degree of stenosis was usually determined by the true and residual lumen of the carotid artery at the atherosclerotic plaque on the transverse image. The Doppler frequency signals were automatically converted to velocity data by a minicomputer. The accuracy of the duplex system in detecting and assessing stenoses graded in 20% increments is demonstrated according to specificity, sensitivity, and positive and negative predictive value by both cumulative and subgroup analyses. A 93.7% sensitivity was shown for minimal (0-20%) stenosis and 100% sensitivity for severe (greater than 60%) stenosis. An apparent limitation of duplex sonography is the differentiation of a high-grade stenosis from occlusion (sensitivity, 82.6%; positive predictive value, 90.4%).
منابع مشابه
Preoperative evaluation of carotid artery stenosis: comparison of contrast-enhanced MR angiography and duplex sonography with digital subtraction angiography.
BACKGROUND AND PURPOSE Contrast-enhanced MR angiography and extracranial color-coded duplex sonography are noninvasive, preoperative imaging modalities for evaluation of carotid artery stenosis. Innovative techniques and improvements in image quality require frequent reassessment of accuracy, reliability, and diagnostic value compared with those of digital subtraction angiography (DSA). We eval...
متن کاملبررسی تنگی عروق کاروتید داخلی در مبتلایان به حملات ایسکمی گذرا در بیمارستان امام خمینی در سال های 1375 تا 1377
This is a prospective descriptive research which was carried out in Imam Khomeini Hospital related to Tehran University during two years (1375-1377) in order to study the incidence of internal carotid stenosis in patients who suffered from TIA ot minor stroke. It was evaluated by duplex sonography. Risk factors of carotid stenosis were studied. 1052 patients who had cerebrovascular accident adm...
متن کاملCommon carotid artery occlusion: evaluation with duplex sonography.
PURPOSE To demonstrate the efficacy of carotid duplex ultrasound to diagnose common carotid artery occlusion (CCAO) and to define the clinical features of CCAO. METHODS We reviewed 5400 carotid duplex ultrasonograms obtained over a 7-year period for suspected carotid artery disease. In cases of CCAO, medical records were reviewed. RESULTS Thirteen cases (0.24%) of CCAO were diagnosed by car...
متن کاملDuplex sonography for carotid artery disease: an accurate technique.
Carotid arteriograms and combined real-time B-mode and Doppler sonograms were evaluated by independent observers of 101 carotid arteries in 51 consecutive patients. The results were correlated . For Duplex detection of hemodynamically significant stenosis, a specificity of 97% was obtained, sensitivity of 94%, and accuracy of 96% . The Duplex examination is an accurate method for evaluating car...
متن کاملEvaluation of revascularization after total arch replacement in common carotid artery occlusion
Occlusion of the common carotid artery (CCA) is rare. CCA occlusion (CCAO) can present as drowsiness and right hemiplegia related to emboli after total arch replacement. Although we selected a follow-up at first because color duplex sonography showed retrograde flow from the left external carotid artery to the internal carotid artery, this patient had epilepsy and single-photon emission compute...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 4 3 شماره
صفحات -
تاریخ انتشار 1983