Comparison of the efficacy of a demand oxygen delivery system with continuous low flow oxygen in subjects with stable COPD and severe oxygen desaturation on walking.
نویسندگان
چکیده
BACKGROUND Provision of ambulatory oxygen using an intermittent pulsed flow regulated by a demand oxygen delivery system (DODS) greatly increases the limited supply time of standard portable gaseous cylinders. The efficacy of such a system has not previously been studied during submaximal exercise in subjects with severe chronic obstructive pulmonary disease (COPD) in whom desaturation is likely to be great and where usage is often most appropriate. METHODS Fifteen subjects with severe COPD and oxygen desaturation underwent six minute walk tests performed in random order to compare the efficacy of a demand oxygen delivery system (DODS) with continuous flow oxygen. Walk distance, breathlessness, oxygen saturation, resting time, and recovery time (objective and subjective) were recorded and compared for each walk. RESULTS Breathing continuous oxygen compared with baseline air breathing improved mean walk distance (295 m versus 271 m) and recovery time (47 seconds versus 112 seconds), whilst the lowest recorded saturation (81% versus 74%) and time desaturated below 90% (201 seconds versus 299 seconds) were reduced. When the DODS was compared with air breathing only the walk distance changed (283 m versus 271 m). A comparison of the DODS with continuous oxygen breathing showed the DODS to be less effective at oxygenating subjects with inferior lowest saturation (78% versus 81%), time spent below 90% (284 seconds versus 201 seconds), time to objective recovery (83 seconds versus 47 seconds), and walk distance (283 m versus 295 m). CONCLUSIONS Neither of the delivery systems was able to prevent desaturation in these subjects. The use of continuous flow oxygen, however, was accompanied by improvements in oxygenation, walk distance, and recovery time compared with air breathing. The DODS produced only a small increase in walk distance without elevation of oxygen saturation, but was inferior to continuous flow oxygen in most of the measured variables when compared directly.
منابع مشابه
RESPONSES OF OXYGEN CONSUMPTION, HEART RATE AND PERCEIVED EXERTION TO CRUTCH WALKING: A COMPARISON BE TWEEN PAR APLEGIC AND ABLE-BODIED SUBJECTS
In this study, 10 normal volunteers and 5 sports-trained paraplegics with lesions between T6 and L2 were studied whilst walking with axillary crutches and knee-anlde-foot orthoses. All subjects walked at their preferred speed on a figureof- eight track. Normal subjects also walked at slower and faster speeds. Oxygen consumption, heart rate and rating of perceived exertion were measured. In...
متن کاملAre oxygen-conserving devices effective for correcting exercise hypoxemia?
BACKGROUND Correction of exercise hypoxemia in advanced lung diseases is crucial and often challenging. However, oxygen-conserving devices have been introduced in the market with limited evidence of effectiveness. In the present study the efficacy of 2 oxygen-conserving devices, a pulse demand oxygen delivery (DOD) system and pendant reservoir cannula (PRC), were evaluated in subjects with COPD...
متن کاملShort report Evaluation of pulsed dose oxygen delivery during exercise in patients with severe chronic obstructive pulmonary disease
Background—Oxygen conserving devices may lead to substantial increases in the duration of oxygen provided. A study was undertaken to compare the performance of a pulsed dose oxygen delivery (PDOD) system with continuous flow oxygen or air during a maximal walking test. Methods—Fourteen patients with chronic obstructive pulmonary disease (COPD) and arterial oxygen desaturation on exercise (mean ...
متن کاملModeling and optimization of oil refinery wastewater chemical oxygen demand removal in dissolved air flotation system by response surface methodology
In this present study the dissolved air flotation (DAF) system was investigated for the treatment of Kermanshah Oil Refinery wastewater. The effect of three parameters on flotation efficiency including of flow rate (outflow from the flotation tank), saturation pressure and coagulant dosage on chemical oxygen demand (COD) removal was examined experimentally. All the experiments were done under a...
متن کاملNocturnal efficiency and tolerance of a demand oxygen delivery system in COPD patients with nocturnal hypoxemia.
OBJECTIVES We compared the efficacy of the standard nasal cannula and the demand oxygen delivery system (DODS) during sleep in patients with COPD. SUBJECTS Twenty patients with moderate or severe COPD were included in the study. METHODS Four consecutive polysomnographic recordings were performed under the following conditions: DODS powered by compressed air (night 1 [N1]); oxygen delivered ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 51 8 شماره
صفحات -
تاریخ انتشار 1996