Deep vein thrombosis using noncontrast-enhanced MR venography with electrocardiographically gated three-dimensional half-Fourier FSE: preliminary experience.

نویسندگان

  • Atsushi Ono
  • Kenya Murase
  • Toshitaka Taniguchi
  • Osamu Shibutani
  • Satoru Takata
  • Yasuyuki Kobashi
  • Mitsue Miyazaki
چکیده

Three noncontrast-enhanced MR venography techniques are presented for assessing deep vein thrombosis (DVT) at 0.5 T in patients with metallic implants. Two cardiac-gated 3D half-Fourier FSE fresh blood imaging sequences with flow-refocusing pulses (FR-FBI) in the read-out (RO) direction and without FR pulses (non-FR-FBI) were developed for slower-flowing blood. For faster flowing blood, a swap phase-encode arterial double-subtraction elimination (SPADE) technique was developed. The three techniques were assessed both quantitatively using signal-to-noise (SNR) and contrast-noise-ratio (CNR) measurements and qualitatively by subjective image analysis in 15 volunteers. SPADE was compared to FR-FBI in the pelvic veins and FR-FBI was compared to non-FR-FBI in the thigh and calf veins. Both SPADE and FR-FBI techniques produced significantly higher SNRs, CNRs, and image quality in each comparative study (P<0.001). Five patients with metallic implants and confirmed DVT underwent SPADE (pelvic veins) and FR-FBI (thigh and calf veins) examinations and the results were compared to conventional venography. The SPADE and FR-FBI images showed all DVTs from all five patients without interference from implant susceptibility artifacts. The excellent image quality produced by both SPADE and FR-FBI throughout peripheral vasculature demonstrates their promise for detecting DVT in postsurgery patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deep venous thrombosis: diagnostic value of non-contrast-enhanced MR venography using electrocardiography-triggered three-dimensional half-Fourier FSE.

We prospectively assessed the diagnostic accuracy of non-contrast-enhanced MR venography using both the flow-refocused fresh-blood imaging (FR-FBI) and the swap phase-encode arterial double-subtraction elimination (SPADE) techniques for detecting deep vein thrombosis (DVT), as compared using conventional X-ray venography as the reference standard. Forty-one legs of 32 consecutive patients (eigh...

متن کامل

Non-contrast-enhanced MR Portography using spin labeling technique: comparison of balanced SSFP and half-Fourier FSE sequence

PURPOSE Several MRA techniques have been implemented for non-invasive imaging of the portal vein. A time-spatial labeling inversion pulse (time-SLIP) technique was reported using a free hand spatial selection and tag-on and tag-off alternating scan and MIP processing to only depict the marked blood while canceling the background signals at any specified inversion time [1]. The purpose of this s...

متن کامل

MR Venography for the Assessment of Deep Vein Thrombosis in Lower Extremities with Varicose Veins.

OBJECTIVE To assess the performance of magnetic resonance venography (MRV) for pelvis and deep vein thrombosis in the lower extremities before surgical interventions for varicose veins. MATERIALS AND METHODS We enrolled 72 patients who underwent MRV and ultrasonography before stripping for varicose veins of lower extremities. All images of the deep venous systems were evaluated by time-of-fli...

متن کامل

CLINICAL PROGRESS Deep Vein Thrombosis

In the articles below three contributors discuss recent progress in the diagnosis and medical and surgical management of deep vein thrombosis. Mr. Norman Browse concludes that not only is phlebography the most valuable method for diagnosis but that it may help correct management. Dr. P. T. ilute emphasizes that anticoagulants may be ineffective in preventing pulmonary embolism from recent throm...

متن کامل

[Evaluation of the detectability of vascular stenosis using non-contrast magnetic resonance angiography with various electrocardiographically-gated three-dimensional fast spin echo sequences].

Various three-dimensional fast spin echo (3D-FSE) sequences are used for non-contrast magnetic resonance angiography (MRA). Differences in the ability to detect vascular stenosis using these sequences, however, have not yet been evaluated. The purpose of this study is to evaluate the usefulness of each sequence for the detection of vascular stenosis by using a vascular phantom. The phantom cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 2009