The highly accurate anteriolateral portal for injecting the knee
نویسندگان
چکیده
BACKGROUND The extended knee lateral midpatellar portal for intraarticular injection of the knee is accurate but is not practical for all patients. We hypothesized that a modified anteriolateral portal where the synovial membrane of the medial femoral condyle is the target would be highly accurate and effective for intraarticular injection of the knee. METHODS 83 subjects with non-effusive osteoarthritis of the knee were randomized to intraarticular injection using the modified anteriolateral bent knee versus the standard lateral midpatellar portal. After hydrodissection of the synovial membrane with lidocaine using a mechanical syringe (reciprocating procedure device), 80 mg of triamcinolone acetonide were injected into the knee with a 2.0-in (5.1-cm) 21-gauge needle. Baseline pain, procedural pain, and pain at outcome (2 weeks and 6 months) were determined with the 10 cm Visual Analogue Pain Score (VAS). The accuracy of needle placement was determined by sonographic imaging. RESULTS The lateral midpatellar and anteriolateral portals resulted in equivalent clinical outcomes including procedural pain (VAS midpatellar: 4.6 ± 3.1 cm; anteriolateral: 4.8 ± 3.2 cm; p = 0.77), pain at outcome (VAS midpatellar: 2.6 ± 2.8 cm; anteriolateral: 1.7 ± 2.3 cm; p = 0.11), responders (midpatellar: 45%; anteriolateral: 56%; p = 0.33), duration of therapeutic effect (midpatellar: 3.9 ± 2.4 months; anteriolateral: 4.1 ± 2.2 months; p = 0.69), and time to next procedure (midpatellar: 7.3 ± 3.3 months; anteriolateral: 7.7 ± 3.7 months; p = 0.71). The anteriolateral portal was 97% accurate by real-time ultrasound imaging. CONCLUSION The modified anteriolateral bent knee portal is an effective, accurate, and equivalent alternative to the standard lateral midpatellar portal for intraarticular injection of the knee. TRIAL REGISTRATION ClinicalTrials.gov: NCT00651625.
منابع مشابه
Aspiration and Injection of the Knee Joint: Approach Portal
Aspiration and injection of the knee joint is a commonly performed medical procedure. Injection of corticosteroid for the treatment of osteoarthritis is the most common reason for knee joint injection, and is performed as an office procedure. Debate exists among practitioners as to the 'best' approach portal for knee injection. This paper examines the various approach portals for injection and/...
متن کاملARTHROSCOPIC MODIFIED ALL-INSIDE LATERAL MENISCAL TEAR REPAIR USING TWO POSTERIOR PORTAL TECHNICAL NOTE
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملصحت تشخیصی پارامترهای شریان کبدی و ورید پورت در داپلر سونوگرافی سیروز
Background: Cirrhosis and portal hypertension influence the hepatic circulation. The purpose of this study was to evaluate the diagnostic accuracy of liver Doppler ultrasonography parameters in cirrhosis.Methods: This case-control study involved 118 subjects. All case subjects had biopsy-proven hepatic cirrhosis. The controls were healthy people, case-matched for age and gender. All cases and c...
متن کاملAssessment effectiveness of hypertonic dextrose prolotherapy compared with erythropoietin, platelet-rich plasma and radiofrequency prolotherapy in knee osteoarthritis treatment in Iran
Aims and background: Knee osteoarthritis (OA) is a major public health issue because it causes chronic pain, reduces physical function and diminishes quality of life. Knee osteoarthritis is a chronic disease and is one of the most common causes of disability in the elderly. Population ageing and increased global prevalence of obesity are anticipated to dramatically increase the prevalence of kn...
متن کاملA New Highly Controllable and Accurate Algorithm for Defuzzifier Circuit Implementation
Defuzzifier circuit is one of the most important parts of fuzzy logic controllers that determine the output accuracy. The Center Of Gravity method (COG) is one of the most accurate methods that so far been presented for defuzzification. In this paper, a simple algorithm is presented to generate triangular output membership functions in the Mamdani method using the multiplier/divider circuit and...
متن کامل