Comparison of vertical ground reaction forces during overground and treadmill running. A validation study

نویسندگان

  • Bas Kluitenberg
  • Steef W Bredeweg
  • Sjouke Zijlstra
  • Wiebren Zijlstra
  • Ida Buist
چکیده

BACKGROUND One major drawback in measuring ground-reaction forces during running is that it is time consuming to get representative ground-reaction force (GRF) values with a traditional force platform. An instrumented force measuring treadmill can overcome the shortcomings inherent to overground testing. The purpose of the current study was to determine the validity of an instrumented force measuring treadmill for measuring vertical ground-reaction force parameters during running. METHODS Vertical ground-reaction forces of experienced runners (12 male, 12 female) were obtained during overground and treadmill running at slow, preferred and fast self-selected running speeds. For each runner, 7 mean vertical ground-reaction force parameters of the right leg were calculated based on five successful overground steps and 30 seconds of treadmill running data. Intraclass correlations (ICC₃,₁) and ratio limits of agreement (RLOA) were used for further analysis. RESULTS Qualitatively, the overground and treadmill ground-reaction force curves for heelstrike runners and non-heelstrike runners were very similar. Quantitatively, the time-related parameters and active peak showed excellent agreement (ICCs between 0.76 and 0.95, RLOA between 5.7% and 15.5%). Impact peak showed modest agreement (ICCs between 0.71 and 0.76, RLOA between 19.9% and 28.8%). The maximal and average loading-rate showed modest to excellent ICCs (between 0.70 and 0.89), but RLOA were higher (between 34.3% and 45.4%). CONCLUSIONS The results of this study demonstrated that the treadmill is a moderate to highly valid tool for the assessment of vertical ground-reaction forces during running for runners who showed a consistent landing strategy during overground and treadmill running. The high stride-to-stride variance during both overground and treadmill running demonstrates the importance of measuring sufficient steps for representative ground-reaction force values. Therefore, an instrumented treadmill seems to be suitable for measuring representative vertical ground-reaction forces during running.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COMPARING EFFICIENCY OF EXERCISE ON THE TREADMILL AND GROUND ON THE GROUND REACTION FORCES DURING WALKING IN PEOPLE WITH GENU VARUM

Background & Aim: Genu varum is one of the most common abnormalities of the knee joint in which the inner condyles of the femur move away from each other. The aim of the present study was to compare efficiency of exercise on the treadmill and ground on the ground reaction forces during walking in people with genu varum. Material & Methods: The present study was a quasi-experimental and laborat...

متن کامل

Joint kinematics and kinetics of overground accelerated running versus running on an accelerated treadmill.

Literature shows that running on an accelerated motorized treadmill is mechanically different from accelerated running overground. Overground, the subject has to enlarge the net anterior-posterior force impulse proportional to acceleration in order to overcome linear whole body inertia, whereas on a treadmill, this force impulse remains zero, regardless of belt acceleration. Therefore, it can b...

متن کامل

The Effects of Changing Footstrike Pattern on the Amplitude and Frequency Spectrum of Ground Reaction Forces During Running in Individuals With Pronated Feet

Background: The current study aimed to evaluate the effects of barefoot and shod running with two different styles on ground reaction force-frequency content in recreational runners with low arched feet. Methods: The statistical sample of this research was 13 males with PF (mean±SD age: 26.2±2.8 y; height: 176.1±8.4 cm; weight: 78.3±14.3 kg). A force plate (Bertec, USA) with a sample rate of 1...

متن کامل

Immediate effects of femoral external rotational and abductoral taping on ground reaction force characteristics during running

Introduction and aim: Taping is a common method used by athletes to improve muscular function. The aim was to assess the immediate effect of femoral external rotational and abductoral taping on three-dimensional ground reaction force characteristics, their time to peak, impulse, displacement of center of pressure, vertical loading rate, and free moment during stance phase of running. Method: 24...

متن کامل

Comparing the Effects of Fatigue Caused by the Treadmill and Overground Running on the Pattern of Plantar Pressure Distribution

Purpose: This study aimed to compare the effects of fatigue due to overground and treadmill running on the plantar pressure distribution pattern.  Methods: Twelve novice athletes (Mean±SD age=26.0±2.5 y, Mean±SD weight: 52.0±3.0 kg, Mean±SD height: 159.0±5.0 cm), without sports injuries over the past year, were selected. Overground and treadmill running created fatigue in the samples. Peak pla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012