Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system

نویسندگان

  • Christian Antfolk
  • Christian Balkenius
  • Göran Lundborg
  • Birgitta Rosén
  • Fredrik Sebelius
چکیده

BACKGROUND The users of today's commercial prosthetic hands are not given any conscious sensory feedback. To overcome this deficiency in prosthetic hands we have recently proposed a sensory feedback system utilising a "tactile display" on the remaining amputation residual limb acting as man-machine interface. Our system uses the recorded pressure in a hand prosthesis and feeds back this pressure onto the forearm skin. Here we describe the design and technical solution of the sensory feedback system aimed at hand prostheses for trans-radial/humeral amputees. Critical parameters for the sensory feedback system were investigated. METHODS A sensory feedback system consisting of five actuators, control electronics and a test application running on a computer has been designed and built. Firstly, we investigate which force levels were applied to the forearm skin of the user while operating the sensory feedback system. Secondly, we study if the proposed system could be used together with a myoelectric control system. The displacement of the skin caused by the sensory feedback system would generate artefacts in the recorded myoelectric signals. Accordingly, EMG recordings were performed and an analysis of the these are included. The sensory feedback system was also preliminarily evaluated in a laboratory setting on two healthy non-amputated test subjects with a computer generating the stimuli, with regards to spatial resolution and force discrimination. RESULTS We showed that the sensory feedback system generated approximately proportional force to the angle of control. The system can be used together with a myoelectric system as the artefacts, generated by the actuators, were easily removed using a simple filter. Furthermore, the application of the system on two test subjects showed that they were able to discriminate tactile sensation with regards to spatial resolution and level of force. CONCLUSIONS The results of these initial experiments in non-amputees indicate that the proposed tactile display, in its simple form, can be used to relocate tactile input from an artificial hand to the forearm and that the system can coexist with a myoelectric control systems. The proposed system may be a valuable addition to users of myoelectric prosthesis providing conscious sensory feedback during manipulation of objects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of methods for constructing gloves with tactile and force feedback for virtual reality and telecontrol of anthropomorphic manipulators

Aims. Devices that allow using the functionality of natural hand movements are of the greatest interest. The purpose of this study is to select areas of research at the intersection of several fields of science – biomechanics and cybernetics to develop scientific and technical approaches to track the movements of the operator's fingers and form feedback tactile and force communication received ...

متن کامل

Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin.

OBJECTIVE Lack of sensory feedback is a drawback in today's hand prostheses. We present here a non-invasive simple sensory feedback system, which provides the user of a prosthetic hand with sensory feedback on the arm stump. It is mediated by air in a closed loop system connecting silicone pads on the prosthetic hand with pads on the amputation stump. The silicone pads in a "tactile display" on...

متن کامل

Determining the Proper compression Algorithm for Biomedical Signals and Design of an Optimum Graphic System to Display Them (TECHNICAL NOTES)

In this paper the need for employing a data reduction algorithm in using digital graphic systems to display biomedical signals is firstly addressed and then, some such algorithms are compared from different points of view (such as complexity, real time feasibility, etc.). Subsequently, it is concluded that Turning Point algorithm can be a suitable one for real time implementation on a microproc...

متن کامل

Design and Construction of a New Capacitive Tactile Sensor for Measuring Normal Tactile Force

This paper presents the design, construction and testing of a new capacitive tactile sensor for measurement of normal tactile force. The operation of proposed sensor has been investigated in ASTABLE and MONOSTABLE circuits. According to the results of these circuits the deviation of ASTABLE circuit results is less than MONOSTABLE circuit results. In addition, the results obtained from ASTABLE c...

متن کامل

Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. Antfolk,

(2012). Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with thes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2010