MoS₂ field-effect transistor for next-generation label-free biosensors.
نویسندگان
چکیده
Biosensors based on field-effect transistors (FETs) have attracted much attention, as they offer rapid, inexpensive, and label-free detection. While the low sensitivity of FET biosensors based on bulk 3D structures has been overcome by using 1D structures (nanotubes/nanowires), the latter face severe fabrication challenges, impairing their practical applications. In this paper, we introduce and demonstrate FET biosensors based on molybdenum disulfide (MoS2), which provides extremely high sensitivity and at the same time offers easy patternability and device fabrication, due to its 2D atomically layered structure. A MoS2-based pH sensor achieving sensitivity as high as 713 for a pH change by 1 unit along with efficient operation over a wide pH range (3-9) is demonstrated. Ultrasensitive and specific protein sensing is also achieved with a sensitivity of 196 even at 100 femtomolar concentration. While graphene is also a 2D material, we show here that it cannot compete with a MoS2-based FET biosensor, which surpasses the sensitivity of that based on graphene by more than 74-fold. Moreover, we establish through theoretical analysis that MoS2 is greatly advantageous for biosensor device scaling without compromising its sensitivity, which is beneficial for single molecular detection. Furthermore, MoS2, with its highly flexible and transparent nature, can offer new opportunities in advanced diagnostics and medical prostheses. This unique fusion of desirable properties makes MoS2 a highly potential candidate for next-generation low-cost biosensors.
منابع مشابه
A simulation study on the performance of various label-free electronic biosensors
The efficient detection of charged biomolecules by biosensor with appropriate semiconducting nanomaterials and with optimum device geometry has caught tremendous research interest in the present decade. Here, the performance of various label-free electronic biosensors to detect bio-molecules is investigated by simulation technique. Silicon nanowire sensor, nanosphere sensor and double gate fiel...
متن کاملA simulation study on the performance of various label-free electronic biosensors
The efficient detection of charged biomolecules by biosensor with appropriate semiconducting nanomaterials and with optimum device geometry has caught tremendous research interest in the present decade. Here, the performance of various label-free electronic biosensors to detect bio-molecules is investigated by simulation technique. Silicon nanowire sensor, nanosphere sensor and double gate fiel...
متن کاملAdvances in nanowire bioelectronics.
Semiconductor nanowires represent powerful building blocks for next generation bioelectronics given their attractive properties, including nanometer-scale footprint comparable to subcellular structures and bio-molecules, configurable in nonstandard device geometries readily interfaced with biological systems, high surface-to-volume ratios, fast signal responses, and minimum consumption of energ...
متن کاملField effect transistor nanobiosensors: State-of-the-art and key challenges as point of care testing devices
The existing health care systems focus on treating diseases rather than preventing them. Patients are generally not tested unless physiological symptoms are appeared. When they do get tested, the results often take several days and can be inconclusive if the disease is at an early stage. In order to facilitate the diagnostics process and make tests more readily available for patients, the conce...
متن کاملGate structural engineering of MOS-like junctionless Carbon nanotube field effect transistor (MOS-like J-CNTFET)
In this article, a new structure is presented for MOS (Metal Oxide Semiconductor)-like junctionless carbon nanotube field effect transistor (MOS-like J-CNTFET), in which dual material gate with different work-functions are used. In the aforementioned structure, the size of the gates near the source and the drain are 14 and 6 nm, respectively, and the work-functions are equal and 0.5 eV less tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- ACS nano
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2014