Three-dimensional images of extra-anatomic arterial bypass graft using multidetector row spiral computed tomography data with volume rendering.
نویسندگان
چکیده
A71-year-old patient was referred to our department for postoperative evaluation of an extra-anatomic aortobifemoral bypass graft (Dacron) from the distal thoracic aorta to both common femoral arteries. Eight days earlier, the patient had undergone surgical resection of an anastomotic aneurysm, with interposition of a short new graft segment at the right distal anastomosis of the bypass graft. The extraanatomic aortobifemoral bypass had been implanted 9 years previously due to a severe infection of an infrarenal aortic bifurcation prosthesis. At that time, the infected prosthesis was removed, with subsequent ligation of the infrarenal abdominal aorta. Multidetector row spiral computed tomography (MDCT) angiography (Somatom Volume Zoom, Siemens AG) was performed after the administration of 120 mL of iodixanol (Visipaque 300, Nycomed Amersham Imaging AS) at a flow rate of 3 mL/s using a power injector. The entire anatomic area from the supraaortic vessels down to the femoral arteries was scanned within 1 breathhold by using a collimation of 2.5 mm and a table feed of 25 mm/s. Images were reconstructed with a slice width of 3 mm and a reconstruction interval of 2 mm. Three-dimensional volume-rendering images of the MDCT data sets were performed (Figures 1 and 2 and Online Figure I). MDCT angiography allowed evaluation of the entire extraanatomic aortobifemoral bypass graft. Proximal and distal graft anastomosis could be evaluated in detail. The presence of vascular clips used for vessel ligation did not alter image quality. Retrograde filling of contrast material into the left internal and right external artery was visible. Otherwise, no abnormal finding of the extra-anatomic bypass graft was detected on MDCT angiography. The patient was discharged on the eighth postoperative day.
منابع مشابه
Evaluation of hepatic vascular anatomy by multidetector computed tomography angiography in living liver right lobe donors
Background and Aims: The purpose of this study was to demonstrate the hepatic vascular anatomy and the variations in living right lobe donors by multidetector computed tomography angiography before the transplantation surgery and to detect the prevalence of these variations. Materials and Methods: Fifty-one potential liver donors (20 females, 31 males) underwent hepatic vascular computed tomogr...
متن کاملInteractive three-dimensional volume rendering of spiral CT data: current applications in the thorax.
Spiral computed tomographic (CT) data sets coupled with a real-time volume-rendering technique allow creation of accurate three-dimensional (3D) images that can be used for a wide range of clinical applications. The image contrast of and relative pixel attenuations in the final image can be interactively modified by the user in real time by manipulating trapezoidal transfer functions. Although ...
متن کاملThree-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملIntroduction to the Language of Three - dimensional Imaging with Multidetector CT 1 Neal
The recent proliferation of multi–detector row computed tomography (CT) has led to an increase in the creation and interpretation of images in planes other than the traditional axial plane. Powerful three-dimensional (3D) applications improve the utility of detailed CT data but also create confusion among radiologists, technologists, and referring clinicians when trying to describe a particular...
متن کاملThree-dimensional volume rendering of spiral CT data: theory and method.
Three-dimensional (3D) medical images of computed tomographic (CT) data sets can be generated with a variety of computer algorithms. The three most commonly used techniques are shaded surface display, maximum intensity projection, and, more recently, 3D volume rendering. Implementation of 3D volume rendering involves volume data management, which relates to operations including acquisition, res...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 104 25 شماره
صفحات -