Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
نویسندگان
چکیده
BACKGROUND Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. METHODS AND RESULTS Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D 'clouds' of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r2 = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors. CONCLUSION Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.
منابع مشابه
Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملA novel phantom design for brachytherapy quality assurance
Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...
متن کاملRole of Magnesium Sulfate in Preventing Vasospasm and Maintaining Hemodynamic Stability in Patients Undergoing Endovascular Coiling for Brain Aneurysm
Introduction: Themaintenance of hemodynamic stability in brain aneurysm surgery has paramount clinical significance in order to prevent vasospasm in the patients with aneurysmal subarachnoid hemorrhage. Regarding this, the present study was conducted to assess the role of magnesium sulfate in preventing vasospasm and maintaining hemodynamic stability during endovascular coiling procedure for br...
متن کاملOptical coherence tomography after carotid stenting: rate of stent malapposition, plaque prolapse and fibrous cap rupture according to stent design.
OBJECTIVES This study aims to evaluate the rate of stent malapposition, plaque prolapse and fibrous cap rupture detected by optical coherence tomography (OCT) imaging according to carotid stent design. DESIGN It was a prospective single-centre study. MATERIALS AND METHODS Forty consecutive patients undergoing protected carotid artery stenting (CAS) and high-definition OCT image acquisition ...
متن کاملAssessment of Dentists’ knowledge of Peri-Implant Inflammatory Diseases and Their Related Treatment in Rasht
Introdouction: Implants are considered to be a useful treatment for the replacement of lost teeth. Although the success rate and durability of implants are high, the prevalence of peri-implantitis is high as well. The purpose of this study was to analyze the knowledge of general practitioners in the city of Rasht in Northern Iran regarding peri-implantitis and its treatment. Materials and meth...
متن کامل