C1lc20654k 3698..3702

نویسندگان

  • Shuo Pang
  • Chao Han
  • Lap Man Lee
  • Changhuei Yang
چکیده

We report the implementation of an on-chip microscope system, termed fluorescence optofluidic microscope (FOFM), which is capable of fluorescence microscopy imaging of samples in fluid media. The FOFM employs an array of Fresnel zone plates (FZP) to generate an array of focused light spots within a microfluidic channel. As a sample flows through the channel and across the array of focused light spots, the fluorescence emissions are collected by a filter-coated CMOS sensor, which serves as the channel’s floor. The collected data can then be processed to render fluorescence microscopy images at a resolution determined by the focused light spot size (experimentally measured as 0.65 mmFWHM). In our experiments, our established resolution was 1.0 mm due to Nyquist criterion consideration. As a demonstration, we show that such a system can be used to image the cell nuclei stained by Acridine Orange and cytoplasm labeled by Qtracker .

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescence microscopy imaging with a Fresnel zone plate array based optofluidic microscope.

We report the implementation of an on-chip microscope system, termed fluorescence optofluidic microscope (FOFM), which is capable of fluorescence microscopy imaging of samples in fluid media. The FOFM employs an array of Fresnel zone plates (FZP) to generate an array of focused light spots within a microfluidic channel. As a sample flows through the channel and across the array of focused light...

متن کامل

Genome Sequence of Lactobacillus rhamnosus Strain CNCM I-3698

Lactobacillus rhamnosus CNCM I-3698 is a commercially available probiotic that is used in animal feed as an additive. Here, we announce the draft genome sequence for this strain, consisting of 71 contigs corresponding to 2,966,480 bp and a G+C content of 46.69%.

متن کامل

Full agonistic properties of BAY x 3702 on presynaptic and postsynaptic 5-HT1A receptors electrophysiological studies in the rat hippocampus and dorsal raphe.

The present studies evaluated the effects of acute and long-term administration of the 5-HT1A agonist BAY x 3702 on the responsiveness of dorsal raphe 5-HT neurons and of dorsal hippocampus CA3 pyramidal neurons. BAY x 3702 potently reduced the firing activity of 5-HT neurons and of CA3 pyramidal neurons when applied by microiontophoresis and this inhibitory effect of BAY x 3702 was fully antag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011