Thoracic CT-PET Registration Using a 3D Breathing Model
نویسندگان
چکیده
In the context of thoracic CT-PET volume registration, we present a novel method to incorporate a breathing model in a non-linear registration procedure, guaranteeing physiologically plausible deformations. The approach also accounts for the rigid motions of lung tumors during breathing. We performed a set of registration experiments on one healthy and four pathological data sets. Initial results demonstrate the interest of this method to significantly improve the accuracy of multimodal volume registration for diagnosis and radiotherapy applications.
منابع مشابه
Combining a breathing model and tumor-specific rigidity constraints for registration of CT-PET thoracic data.
Diagnosis and therapy planning in oncology applications often rely on the joint exploitation of two complementary imaging modalities, namely Computerized Tomography (CT) and Positron Emission Tomography (PET). While recent technical advances in combined CT/PET scanners enable 3D CT and PET data of the thoracic region to be obtained with the patient in the same global position, current image dat...
متن کاملCT-PET Landmark-based Registration Using a Dynamic Lung Model
This paper deals with the problem of non-linear landmark-based registration of CT and PET images of thoracic regions. We propose a general method to introduce a breathing model in a registration procedure in order to guarantee physiologically plausible deformations. Initial results are very promising and demonstrate the interest of this method to improve the combination of anatomical and functi...
متن کاملCT and PET Registration Using Deformations Incorporating Tumor-Based Constraints
Registration of CT and PET thoracic images has to cope with deformations of the lungs during breathing. Possible tumors in the lungs usually do not follow the same deformations, and this should be taken into account in the registration procedure. We show in this paper how to introduce tumor-based constraints into a non-linear registration of thoracic CT and PET images. Tumors are segmented by m...
متن کاملNonrigid versus rigid registration of thoracic 18F-FDG PET and CT in patients with lung cancer: an intraindividual comparison of different breathing maneuvers.
UNLABELLED In lung cancer, (18)F-FDG PET, CT, and (18)F-FDG PET/CT are used for noninvasive staging and therapy planning. Even with improved image registration techniques-especially in the modern hybrid PET/CT scanners-inaccuracies in the fusion process may occur, leading to errors in image interpretation. The aim of this study was to investigate by an intraindividual analysis whether, in compa...
متن کاملLow dose interpolated average CT for thoracic PET/CT attenuation correction using an active breathing controller.
PURPOSE The temporal mismatch between PET and standard helical CT (HCT) causes substantial respiratory artifacts in PET reconstructed images when using HCT as the attenuation map. Previously we developed an interpolated average CT (IACT) method for attenuation correction (AC) and demonstrated its merits in simulations. In this study we aim to apply IACT in patients with thoracic lesions using a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 10 Pt 1 شماره
صفحات -
تاریخ انتشار 2007