The ability of pleth variability index to predict the hemodynamic effects of positive end-expiratory pressure in mechanically ventilated patients under general anesthesia.

نویسندگان

  • Olivier Desebbe
  • Cécile Boucau
  • Fadi Farhat
  • Olivier Bastien
  • Jean-Jacques Lehot
  • Maxime Cannesson
چکیده

BACKGROUND Pleth variability index (PVI) is a new algorithm allowing automated and continuous monitoring of respiratory variations in the pulse oximetry plethysmographic waveform amplitude. PVI can predict fluid responsiveness noninvasively in mechanically ventilated patients during general anesthesia. We hypothesized that PVI could predict the hemodynamic effects of 10 cm H2O positive end-expiratory pressure (PEEP). METHODS We studied 21 mechanically ventilated and sedated patients in the postoperative period after coronary artery bypass grafting. Patients were monitored with a pulmonary artery catheter and a pulse oximeter sensor attached to the index finger. Hemodynamic data (cardiac index [CI], PVI, pulse pressure variation, central venous pressure) were recorded at 3 successive tidal volumes (V(T)) (6, 8, and 10 mL/kg body weight) during zero end-expiratory pressure (ZEEP) and then after addition of a 10 cm H2O PEEP for each V(t). Hemodynamically unstable patients were defined as those with a >15% decrease in CI after the addition of PEEP. RESULTS PEEP induced changes in CI and PVI for V(t) of 8 and 10 mL/kg. Hemodynamic instability occurred in 5 patients for a V(T) of 6 mL/kg, in 6 patients for a V(T) of 8 mL/kg, and in 9 patients for a V(T) of 10 mL/kg. For V(T) of 8 mL/kg, a PVI threshold value of 12% during ZEEP predicted hemodynamic instability with a sensitivity of 83% and a specificity of 80% (area under the receiver operating characteristic curve 0.806; P = 0.03). For V(T) of 10 mL/kg, a PVI threshold value of 13% during ZEEP predicted hemodynamic instability with a sensitivity of 78% and a specificity of 83% (area under the receiver operating characteristic curve 0.829; P = 0.01). CONCLUSIONS PVI may be useful in automatically and noninvasively detecting the hemodynamic effects of PEEP when V(T) is >8 mL/kg in ventilated and sedated patients with acceptable sensitivity and specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pleth variability index and respiratory system compliance to direct PEEP settings in mechanically ventilated patients, an exploratory study

OBJECTIVES To analyze the ability of pleth variability index (PVI) and respiratory system compliance (RSC) on evaluating the hemodynamic and respiratory effects of positive end expiratory pressure (PEEP), then to direct PEEP settings in mechanically ventilated critical patients. METHODS We studied 22 mechanically ventilated critical patients in the intensive care unit. Patients were monitored...

متن کامل

Pleth Variability Index predicts fluid responsiveness in critically ill patients

OBJECTIVE To investigate whether the pleth variability index, a noninvasive and continuous tool, can predict fluid responsiveness in mechanically ventilated patients with circulatory insufficiency. DESIGN Prospective study. SETTING Surgical intensive care unit of a university hospital. PATIENTS Forty mechanically ventilated patients with circulatory insufficiency in whom volume expansion ...

متن کامل

Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...

متن کامل

Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?

BACKGROUND Respiratory variations in the pulse oximeter plethysmographic waveform amplitude (deltaPOP) are sensitive to changes in preload and can predict fluid responsiveness in mechanically ventilated patients. However, they cannot be easily calculated from a bedside monitor. Pleth variability index (PVI, Masimo Corp., Irvine, CA) is a new algorithm that automatically calculates deltaPOP. The...

متن کامل

Effect of hypercapnia on pleth variability index during stable propofol: Remifentanil anesthesia

BACKGROUND The pleth variability index (PVI), which is calculated from respiratory variations in the perfusion index (PI), has been shown to predict fluid responsiveness in mechanically ventilated patients; however, vasomotor tone changes induced by hypercapnia can affect PI and hence may slim down the accuracy of PVI. This study was designed to find out the impact of mild hypercapnia on PVI. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 110 3  شماره 

صفحات  -

تاریخ انتشار 2010