Novel CV for Phase Transformation Electrodes
نویسندگان
چکیده
Phase transformation cyclic voltammetry (CV) was developed by integrating mixed-control phase transformation theory and charge transfer effect with traditional CV model. This mixed-control phase transformation CV model was validated by good agreement between experimental CV data and simulated values from phase transformation CV for LiFePO4. The lithium ion diffusion coefficient (10-16 m2 s-1) of LiFePO4 obtained from the phase transformation CV model was 2 orders of magnitude higher than apparent values (10-18 m2 s-1) determined from traditional CV. The low diffusion coefficient from traditional CV is attributed to the disregard of phase transformation. In addition to the lithium ion diffusion coefficient, the interface mobility (on the magnitude of 10-14 m mol J-1 s-1) of the LiFePO4 electrode, which cannot be measured from traditional CV, was obtained using phase transformation CV. Using the phase transformation CV model, the CV curves of LiFePO4 and LiMnPO4 phase transformation electrodes were characterized, and the effects of lithium ion diffusion coefficient, interface mobility, exchange current density, and particle size on the CV profiles of phase transformation electrodes were systemically investigated.
منابع مشابه
Galvanostatic Intermittent Titration Technique for Phase-Transformation Electrodes
A novel galvanostatic intermittent titration technique (GITT) and a novel potentiostatic intermittent titration technique (PITT) for phase-transformation electrodes were developed by integrating mixed control phasetransformation theory with traditional GITT and PITT methods. The contribution of the strain accommodation energy to the thermodynamic driving force for phase transformation was asses...
متن کاملELECTROCHEMICAL BEHAVIOR OF GC, Pt AND Au ELECTRODES MODIFIED WITH THIN FILM OF COBALT HEXACYANOFERRATE
0A thin film of cobalt hexacyanoferrate (CoHCF), an analogue of mixed-valence Prussian blue, was deposited electrochemically on the glassy carbon, platinum and gold electrode surfaces in 0.5M KC1 solution. The electrochemical behavior of these modified electrodes show three couples of redox peaks by CV in a supporting electrolyte solution of 0.5M NaCl, whereas for Au modified electrode only ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملA novel study on the stepwise electrodeposition approach for the synthesis of Pd based nanoparticles, characterization, and their enhanced electrooxidation activities
Herein, a stepwise electrodeposition technique was used to synthesize the Pd based nanoparticles on indium-tin oxide (ITO) electrodes. First of all, Pd nanoparticles were electrodeposited on ITO via one step electrodeposition technique. Furthermore, Au was electrodeposited on Pd. Finally, Co was electrodeposited on Au and Pd electrodeposited ITO electrode via stepwise electrodeposition techniqu...
متن کامل