Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections.

نویسندگان

  • B A Kirkley
  • K A Easley
  • B A Basille
  • J A Washington
چکیده

A controlled clinical comparison was made of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek Release bottle (Roche Diagnostics, Nutley, N.J.). From 6,345 blood culture sets fulfilling minimum criteria for volume of blood cultured, 840 strains were isolated, of which only 691 (82%) were considered to be representative of bloodstream infection according to Centers for Disease Control definitions. Statistically significant differences were found between the systems for the following organisms, which were all detected more frequently in the Isolator system: Staphylococcus aureus (P = 0.0001), Alcaligenes xylosoxidans (P = 0.008), Klebsiella pneumoniae (P = 0.05), Salmonella spp. (P = 0.03), and Candida albicans (P = 0.02). The Septi-Chek Release system required a longer period of time than the Isolator system for detection of the following organisms:S. aureus (P = 0.0001), Enterococcus spp. (P = 0.0001), Enterobacter cloacae (P = 0.03), Escherichia coli (P = 0.0001), Klebsiella oxytoca (P = 0.03), K. pneumoniae (P = 0.02), Pseudomonas aeruginosa (P = 0.002), and C. albicans (P = 0.005). There were 430 episodes of bloodstream infections identified in the study; of these episodes, only those due to S. aureus were detected significantly more frequently (P = 0.0001) by the Isolator system than by the Septi-Chek Release system. However, episodes of bloodstream infections due to S. aureus, Staphylococcus epidermidis, Enterococcus spp., and E. coli were detected significantly faster by the Isolator system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of BACTEC MYCO/F LYTIC and WAMPOLE ISOLATOR 10 (lysis-centrifugation) systems for detection of bacteremia, mycobacteremia, and fungemia in a developing country.

In less-developed countries, studies of bloodstream infections (BSI) have been hindered because of the difficulty and costs of culturing blood for bacteria, mycobacteria, and fungi. During two study periods (study period I [1997] and study period II [1998]), we cultured blood from patients in Malawi by using the BACTEC MYCO/F LYTIC (MFL), ISOLATOR 10 (Isolator), Septi-Chek AFB (SC-AFB), and Sep...

متن کامل

Comparison of the Bactec Peds Plus pediatric blood culture vial with Roche pediatric Septi-Chek for blood cultures from pediatric patients.

Equal volumes of blood from 4,112 blood cultures were inoculated into one Bactec Peds Plus bottle and one Roche Septi-Chek bottle. There were no significant differences in the recoveries of bloodstream pathogens. Initial detection occurred earlier with Bactec Peds Plus, while growth on solid media occurred earlier with Roche Septi-Chek.

متن کامل

Controlled comparison of a new Becton Dickinson agar slant blood culture system with Roche Septi-Chek for the detection of bacteremia and fungemia.

Two commercially available agar slide blood culture systems, Septi-Chek (Roche Diagnostics, Div. Hoffmann-La Roche Inc., Nutley, N.J.) and VACUTAINER agar slant (Becton Dickinson [BD] Vacutainer Systems, Rutherford, N.J.), were compared in 5,628 paired blood cultures from adult patients. The systems were inoculated with equal volumes (5 ml) of blood. There was no statistically significant diffe...

متن کامل

Analysis of 281,797 consecutive blood cultures performed over an eight-year period: trends in microorganisms isolated and the value of anaerobic culture of blood.

The results for 281,797 blood culture sets of specimens collected from adult patients at the Mayo Clinic over an approximately 8-year period (1 November 1984 through 30 November 1992) were analyzed in order to determine whether there were differences in the types of microorganisms isolated over this time and to assess the usefulness of anaerobic culturing of blood. Each blood culture set consis...

متن کامل

Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.

Blood culture bottles that accept up to 10 ml of blood have recently been introduced for the BACTEC nonradiometric blood culture system. The new formulation, designated BACTEC Plus, contains 25 ml of tryptic soy broth, 0.05% sodium polyanetholesulfonate, and mixed resins. In a collaborative study conducted at three university hospitals, we evaluated the BACTEC Plus 26 (BP26) aerobic bottle and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 1993