Chester step test in patients with COPD: reliability and correlation with pulmonary function test results.
نویسندگان
چکیده
BACKGROUND The 5-stage Chester step test assesses aerobic capacity in healthy subjects. It has not been tested in patients with COPD. OBJECTIVE To determine the reliability of the Chester step test in patients with COPD and correlation with pulmonary function test and exercise test results. METHODS Thirty-two patients (mean ± SD FEV(1) 46 ± 15% of predicted) undertook 2 Chester step tests and two 6-min walk tests, on different days, in random order. A subgroup of 11 patients performed incremental cycle ergometry. RESULTS Thirty-one patients performed stage 1 of the Chester step test. Nineteen patients performed stage 2 of the Chester step test. The number of steps was highly reproducible: 66 ± 41 steps vs 68 ± 41 steps. There was no difference in heart rate or S(pO(2)) between the 2 Chester step tests at the peak of exercise or at the end of each stage. There was a significant correlation between number of steps and FEV(1) (r = 0.43, P = .02), and 6-min walk distance (r = 0.60, P = .001). Heart rate increased according to advanced stages of the Chester step test, up to 81 ± 13% of predicted. There was a significant correlation between number of steps and peak heart rate (r = 0.55, P = .001). In the 11 patients who performed the incremental cycling test there was a significant correlation between number of steps and peak work load (r = 0.69, P = .02). In the 6 patients in whom oxygen uptake could be estimated from the Chester step test, oxygen uptake was higher than that measured at the peak of the cycling test (30.8 ± 5.1 mL/kg/min vs 17.4 ± 4.5 mL/kg/min, respectively, P = .001). CONCLUSIONS Despite being highly reproducible, the Chester step test had a very short duration in patients with COPD. The number of steps incremented in each stage seems to be too large for these patients. An adaptation of the Chester step test should be considered for patients with COPD.
منابع مشابه
Validity and reliability of the Chester step test for prediction of the aerobic capacity among Iranian students
Background: Assessment of aerobic capacity is of vital importance in both general community and occupational settings. Valid, reliable and feasible tests are required to indicate the functionality of cardiopulmonary system. The present study was carried out aiming to evaluate the suitability of the Chester step test (CST) as a field test to measure the Iranians’ aerobic capacity. Materials ...
متن کاملThe Evidence of Hyperinflation on Chest X Ray and its Correlation with Air Flow Obstruction in COPD Patients
Introduction: According to the latest statistical and epidemiological studies, COPD will become the fourth leading cause of death in 2030 worldwide. Scientists are studying on methods to diagnose COPD in the patients in early stages, because it is a curable and preventable disease in early stages. In this study, evidences of hyperinflation on ...
متن کاملThe correlation between death anxieties with self-care in elderly patients with chronic obstructive pulmonary disease referring to masih daneshvari hospital, 2018.
Introduction: In elderly patients, the prevalence of chronic diseases, including chronic obstructive pulmonary disease, is increased. COPD causes many problems, including dyspnea, fatigue, depression, malnutrition and limitation in daily activities and death anxiety among patients that can affect their self-care. Method:This study considered as a descriptive-correlation study in 128 elderly wi...
متن کاملRelationship between serum vitamin D and forced expiratory volume in patients with chronic obstructive pulmonary disease (COPD)
Background: Vitamin D deficiency seems to be associated with pulmonary function deterioration. The present study was designed to investigate the relationship between serum vitamin D and forced expiratory volume in patients with chronic obstructive pulmonary disease (COPD). Methods: From September 2011 to April 2012 eighty consecutive patients with COPD presented to an outpatient clinic of Babo...
متن کاملChester step test: assessment of functional capacity and magnitude of cardiorespiratory response in patients with COPD and healthy subjects.
BACKGROUND the assessment of functional capacity in patients with chronic obstructive pulmonary disease (COPD) has been performed by simple and easy to apply methods that mimic everyday activities, such as the Chester step test (TChester). OBJECTIVES to investigate whether TChester is able to differentiate functional capacity and the magnitude of cardiorespiratory response of patients with CO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 56 7 شماره
صفحات -
تاریخ انتشار 2011