Bond strength of acrylic resin to cobalt-chromium alloy treated with the Silicoater MD and Kevloc systems.

نویسندگان

  • S Pesun
  • R D Mazurat
چکیده

BACKGROUND An optimum bond strength at the resin-metal interface of a prosthesis is essential to the success of that prosthesis. Silicoater MD and Kevloc are two systems used to increase bond strength at the resin-metal interface. This study investigated the effect that surface pretreatment and chemical shelf life had on the bond strength of silicoated samples and compared the shear bond strength of the two systems. METHODS Test samples consisted of autocure denture resin attached to cylinders of chrome cobalt that had been treated either with the Silicoater MD or the Kevloc bonding system. The shear strength of the resin-metal interface was tested using a universal testing machine. The following variables were tested: various silicoating pretreatments; shelf-life period of the silanating chemicals; the method of silicoating. The shear strength of repairs using the Kevloc system were also tested. RESULTS Surface pretreatment using aluminium oxide and sandblasting significantly enhanced the shear bond strength. The shelf life of the chemicals used in the silicoating process did not affect the bond strength over a six-week testing period. Samples treated with the Kevloc system showed significantly higher bond-strength values (17.3 +/- 1.7 MPa) and less variability than samples treated with the Silicoater MD system (11 +/- 3.6 MPa). In addition, all the samples repaired with the Kevloc system had bond strengths comparable to the original Kevloc-treated samples. CONCLUSION The Kevloc system has the potential to provide a more optimal resin-metal bonding system, a stronger and more consistent bond and a simpler laboratory technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bond Strength of Acrylic Resin to Cobalt-Chromium Alloy Treated with the Silicoater MD and Kevloc Systems (Résistance d’adhésion de la résine acrylique à l’alliage cobalt-chrome traité avec les systèmes Silicoater MD et Kevloc)

Introduction The bond strength of the resinmetal interface of a prosthesis is a key factor in determining the serviceability of that prosthesis. Separation of the resin from the metal due to a compromised or weak bond can lead to microleakage, discoloration and total separation of the resin from the metal.1,2 Resin-metal bonding systems as an addition to or replacement for conventional mechanic...

متن کامل

Shear bond strength between autopolymerizing acrylic resin and Co-Cr alloy using different primers.

This study aimed to examine the shear bond strength between cobalt chromium alloy and autopolymerizing acrylic resin using experimental primers containing 5, 10, and 15 wt% of 4-methacryloxyethyl trimellitic anhydride or 1, 2, and 3 wt% of 3-methacryloxypropyl-trimethoxysilane comparison to 5 commercial primers (ML primers, Alloy primer, Metal/Zirconia primer, Monobond S, and Monobond plus). Si...

متن کامل

Effect of Primers on the Shear Bond Strength of Two Types of Acrylic Resin to Co-cr Partial Denture Alloy

The absence or poor chemical bonding of acrylic resin to Cobalt-Chromium metal frameworks, often introduces microleakage and bond failure at the interface. The aim of this study was to compare the shear bond strength of sandblasted cast and ingot cobaltchromium alloy to heat-cured and self-cured acrylic resins primed with four different metal primers. Fifty Co-Cr Ingot and fifty cast specimens ...

متن کامل

Micro-Shear Bond Strength of Indirect Composite Resin to Three Different Computer-Milled Cores After Thermocycling

Background and Aim: The aim of this study was to evaluate the micro-shear bond strength of an indirect composite resin to three different types of cores. Materials and Methods: In this in-vitro study, 14 blocks (5×5×2 mm) were designed and milled by computer from cobalt-chromium (Co-Cr) alloy, zirconia, and polyether ether ketone (PEEK). Each sample was treated according to the manufacturer’s ...

متن کامل

The Effect of Metal Primer on the Shear Bond Strength of Denture Base Resin to Base Metal Alloy after Electrolytic Etching and Laser Etching: An In Vitro Study

Background: The purpose of this study was to compare and evaluate the effects of metal primer on the shear bond strength of denture base resin to base metal alloy after electrolytic and laser etching. Materials and Methods: A total of 48 cobalt‐chromium (Co‐Cr) alloy specimens were fabricated. The specimens were divided into 6 groups of 8 specimens each. Group I: Sandblasting (control group). G...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal

دوره 64 11  شماره 

صفحات  -

تاریخ انتشار 1998