Closed circuit rebreathing to achieve inert gas wash-in for multiple breath wash-out

نویسندگان

  • Alex R Horsley
  • Katherine O'Neill
  • Damian G Downey
  • J Stuart Elborn
  • Nicholas J Bell
  • Jaclyn Smith
  • John Owers-Bradley
چکیده

Multiple breath wash-out (MBW) testing requires prior wash-in of inert tracer gas. Wash-in efficiency can be enhanced by a rebreathing tracer in a closed circuit. Previous attempts to deploy this did not account for the impact of CO2 accumulation on patients and were unsuccessful. We hypothesised that an effective rebreathe wash-in could be delivered and it would not alter wash-out parameters. Computer modelling was used to assess the impact of the rebreathe method on wash-in efficiency. Clinical testing of open and closed circuit wash-in-wash-out was performed in healthy controls and adult patients with cystic fibrosis (CF) using a circuit with an effective CO2 scrubber and a refined wash-in protocol. Wash-in efficiency was enhanced by rebreathing. There was no difference in mean lung clearance index between the two wash-in methods for controls (6.5 versus 6.4; p=0.2, n=12) or patients with CF (10.9 versus 10.8; p=0.2, n=19). Test time was reduced by rebreathe wash-in (156 versus 230 s for CF patients, p<0.001) and both methods were well tolerated. End wash-in CO2 was maintained below 2% in most cases. Rebreathe-wash-in is a promising development that, when correctly deployed, reduces wash-in time and facilitates portable MBW testing. For mild CF, wash-out outcomes are equivalent to an open circuit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of functional residual capacity of the lung by partial CO2 rebreathing method during acute lung injury in animals.

BACKGROUND Several techniques for measuring the functional residual capacity (FRC) of the lungs in mechanically ventilated patients have been proposed, each of which is based on either nitrogen wash-out or dilution of tracer gases. These methods are expensive, difficult, time-consuming, impractical, or require an intolerably large change in the fraction of inspired oxygen. We propose a CO(2) wa...

متن کامل

Clinical assessment of a rebreathing method for measuring pulmonary gas transfer.

A rebreathing method for measuring carbon monoxide transfer factor (TLCO) and transfer coefficient (KCO) is evaluated. The test was performed on 42 subjects. Seventeen of these had normal lung function while the remainder suffered from various conditions, most having fibrosing alveolitis. No patients with severe airways obstruction were included in the group. The results were compared with sing...

متن کامل

PDPS: a pulmonary data processing system for assessment of gas exchange properties by multiple gas wash-out.

A data acquisition and processing system for the analysis of inert gas wash-out tests is described. The described system is in clinical use on spontaneously breathing patients as well as on mechanically ventilated Intensive Care patients. It combines several analysis techniques with an aim to provide a deeper insight into the nature of existing ventilation inhomogeneity than the individual tech...

متن کامل

A modeling-based evaluation of isothermal rebreathing for breath gas analyses of highly soluble volatile organic compounds.

Isothermal rebreathing has been proposed as an experimental technique for estimating the alveolar levels of hydrophilic volatile organic compounds (VOCs) in exhaled breath. Using the prototypic test compounds acetone and methanol, we demonstrate that the end-tidal breath profiles of such substances during isothermal rebreathing show a characteristic increase that contradicts the conventional pu...

متن کامل

Systemic recirculation assessed in apnoeic anaesthetized patients using carbon dioxide concentration measurements during stepwise expiration.

BACKGROUND Mixed venous partial pressure of carbon dioxide has often been estimated in anaesthesia, usually by rebreathing techniques. This assumes equilibrium between respired gas and mixed venous blood before significant recirculation can occur, and requires vigorous rebreathing and precise identification of equilibrium. Modern clinical sidestream capnometers do not measure gas composition as...