Viscosity Measurement in Thin Lubricant Films Using Shear Ultrasonic Reflection
نویسندگان
چکیده
When a shear ultrasonic wave is incident on a solid and liquid boundary, the proportion that is reflected depends on the liquid viscosity. This is the basis for some instruments for on-line measurement of bulk liquid viscosity. In machine elements, the lubricant is usually present in a thin layer between two rubbing solid surfaces. The thin film has a different response to an ultrasonic shear wave than liquid in bulk. In this work, this response is investigated with the aim of measuring viscosity in-situ in a lubricating film. The proportion of the wave reflected at a thin layer depends on the layer stiffness. A shear wave is reflected by the shear stiffness of the thin layer. For a thin viscous liquid layer, the stiffness is a complex quantity dependent on the viscosity, wave frequency, and film thickness. This stiffness is incorporated into a quasi-static spring model of ultrasonic reflection. In this way, the viscosity can be determined from shear wave reflection if the oil film thickness is known. The approach has been experimentally evaluated on some static oil film between Perspex plates. Predictions of the spring model gave good measurement up to layer thicknesses of around 15 m. For thicker layers, the shear stiffness reduces to such an extent that almost all the wave is reflected and the difference associated with he layer response is hard to distinguish from background noise.
منابع مشابه
Analysis of an ultrasonic viscosity measurement cell with mode conversion
Theoretical and experimental analyses of a cell that measures the viscosity of liquids using longitudinal to shear wave mode conversion are presented. The measurement method is based on the determination of the complex reflection coefficient (magnitude and phase) of shear waves at a solid-liquid interface. The cell is composed of an ultrasonic transducer, a water buffer, an aluminum prism, a PM...
متن کاملA Method for the Measurement of Hydrodynamic Oil Films Using Ultrasonic Reflection
The measurement of the thickness of an oil film in a lubricated component is essential information for performance monitoring and control. In this work a new method for oil film thickness measurement, based on the reflection of ultrasound, is evaluated for use in fluid film journal bearing applications. An ultrasonic wave will be partially reflected when it strikes a thin layer between two soli...
متن کاملDMMP Sensing Performance of Undoped and Al Doped Nanocrystalline ZnO Thin Films Prepared by Ultrasonic Atomization and Pyrolysis Method
Highly textured undoped (pure) and Al doped ZnO nanocrystalline thin films prepared by ultrasonic atomization and pyrolysis method are reported in this paper. ZnCl2 water solution was converted into fine mist by ultrasonic atomizer (Gapusol 9001 RBI Meylan, France). The mist was pyrolyzed on the glass substrates in horizontal quartz reactor placed in furnace. The Structural and microstructural ...
متن کاملSurface Roughness Effects in Pure Sliding EHL Line Contacts with Carreau-Type Shear-Thinning Lubricants
The influence of transverse surface roughness on EHL characteristics has been investigated numerically using an extensive set of full EHL line contact simulations for shear-thinning lubricants under pure sliding condition. The shear-thinning behavior of lubricant is modeled using Carreau viscosity equation along with Doolittle-Tait equation for lubricant compressibility. The surface roughness i...
متن کاملInfluences of Temperature, Concentration and Shear Rate on Rheological Behavior of Nanofluid: An Experimental Study with Al2O3-MWCNT/10W40 Hybrid Nano-Lubricant
In this experimental study, the rheological behavior of Al2O3-MWCNT (90%:10%)/10W40 hybrid nano-lubricant has been determined at the temperature range of 5°C to 55°C. Al2O3 nanoparticles (average size of 50 nm) and MWCNTs (inner and outer diameter of 2-6 nm and 5-20 nm, respectively) were dispersed in engine oil (10W40) to prepare 0.05%, 0.1%, 0.2...
متن کامل