Sub-ppm multi-gas photoacoustic sensor.
نویسندگان
چکیده
A photoacoustic multi-gas sensor using tuneable laser diodes in the near-infrared region is reported. An optimized resonant configuration based on an acoustic longitudinal mode is described. Automatic tracking of the acoustic resonance frequency using a piezo-electric transducer and a servo electronics is demonstrated. Water vapour, methane and hydrogen chloride have been measured at sub-ppm level in different buffer gas mixtures. The importance of the system calibration in presence of several diluting gases is discussed. Finally, trace gas measurements have been assessed and detection limits (signal-to-noise ratio=3) of 80 ppb at 1651.0 nm for CH(4), 24 ppb at 1368.6 nm for H(2)O and 30 ppb at 1737.9 for HCl have been demonstrated.
منابع مشابه
Electrochemical Sensing of H2S Gas in Air by Carboxylated Multi-walled Carbon Nanotubes
The electrochemical sensor for detecting hydrogen sulfide was fabricated. H2S gas molecules pass through polytetrafluoroethylene membrane with 0.22 mm pore size. Carboxylated multi-walled carbon nanotubes (MWCNTs-COOH) were used to fabricate working and counter electrodes. It can be seen from Field Emission Scanning Electron Microscopy (FESEM) images of the working electrode that...
متن کاملMulti-hydrogenated compounds monitoring in optical fibre manufacturing process by photoacoustic spectroscopy
Sub-ppm hydrogen chloride (HCl) and water vapour (H2O) monitoring using photoacoustic spectroscopy in optical fibre manufacturing is reported. The development and performance of a sensor based on an acoustic resonant configuration is described, and on-site measurements are presented. Two DFB lasers emitting in the 1370 nm and 1740 nm range were used for the detection of H2O and HCl, respectivel...
متن کاملSub-ppm multi gas sensing based on photoacoustic spectroscopy using DFB laser diodes
Sensitive photoacoustic detection of methane (CH4), hydrogen chloride (HCl) and water vapour (H2O) in the near-infrared range using semiconductor DFB lasers is reported. A detection limit of 0.17 ppm of CH4, 0.2 ppm of HCl and 0.024 ppm of H2O (signal-to-noise ratio = 3) is reached using a properly designed photoacoustic cell operating in its first longitudinal mode.
متن کاملIndividually ventilated cages microclimate monitoring using photoacoustic spectroscopy
A multi-gas photoacoustic sensor was developed in order to monitor microclimatic parameters at ppm level from the atmosphere of individually ventilated cages housing mice. Ammonia, water vapour and carbon dioxide were measured on-line and in real-time during two weeks and 24 hours a day. The quality of bedding and the ventilation rate inside the cages has been monitored. The circadian activity ...
متن کاملMolecular relaxation effects in hydrogen chloride photoacoustic detection
A photoacoustic (PA) sensor has been developed to monitor hydrogen chloride at sub-ppm level in the 1740-nm region. The system was designed to control the process in the novel low-water-peak optical fiber manufacturing process. Relaxation effects in hydrogen chloride PA detection in oxygen– helium and nitrogen–helium gas mixtures are presented, showing that the generation of the PA signal is st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
دوره 63 5 شماره
صفحات -
تاریخ انتشار 2006