Measurement of skeletal muscle radiation attenuation and basis of its biological variation

نویسندگان

  • J Aubrey
  • N Esfandiari
  • V E Baracos
  • F A Buteau
  • J Frenette
  • C T Putman
  • V C Mazurak
چکیده

Skeletal muscle contains intramyocellular lipid droplets within the cytoplasm of myocytes as well as intermuscular adipocytes. These depots exhibit physiological and pathological variation which has been revealed with the advent of diagnostic imaging approaches: magnetic resonance (MR) imaging, MR spectroscopy and computed tomography (CT). CT uses computer-processed X-rays and is now being applied in muscle physiology research. The purpose of this review is to present CT methodologies and summarize factors that influence muscle radiation attenuation, a parameter which is inversely related to muscle fat content. Pre-defined radiation attenuation ranges are used to demarcate intermuscular adipose tissue [from -190 to -30 Hounsfield units (HU)] and muscle (-29 HU to +150 HU). Within the latter range, the mean muscle radiation attenuation [muscle (radio) density] is reported. Inconsistent criteria for the upper and lower HU cut-offs used to characterize muscle attenuation limit comparisons between investigations. This area of research would benefit from standardized criteria for reporting muscle attenuation. Available evidence suggests that muscle attenuation is plastic with physiological variation induced by the process of ageing, as well as by aerobic training, which probably reflects accumulation of lipids to fuel aerobic work. Pathological variation in muscle attenuation reflects excess fat deposition in the tissue and is observed in people with obesity, diabetes type II, myositis, osteoarthritis, spinal stenosis and cancer. A poor prognosis and different types of morbidity are predicted by the presence of reduced mean muscle attenuation values in patients with these conditions; however, the biological features of muscle with these characteristics require further investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mass Attenuation Coefficients of Human Body Organs using MCNPX Monte Carlo Code

Introduction: Investigation of radiation interaction with living organs has always been a thrust area in medical and radiation physics. The investigated results are being used in medical physics for developing improved and sensitive techniques and minimizing radiation exposure. In this study, mass attenuation coefficients of different human organs and biological materials such as adipose, blood...

متن کامل

Solitary Psoas Muscle Metastasis of Gastroesphageal Junction Adenocarcinoma

Metastasis of gastroesphageal junction (GEJ) adenocarcinoma in skeletal muscle is rare and primary sites for skeletal muscle metastases are usually lung, renal and colorectal cancer. We have encountered with the first case report of solitary psoas muscle metastasis of GEJ adenocarcinoma. Here we describe a 65 years old man was diagnosed with GEJ adenocarcinoma in tertiary hospital, Tehran, Iran...

متن کامل

Radiation attenuation of boron doped clay for 662, 1173 and 1332 keV gamma rays

Background: Radiation shielding properties is an important for a material wish can be used the photon attenuation coefficients of clay produced using different rate of boron have been measured for the purpose of radioactive waste disposal. Materials and Methods: The measurement has been performed using gamma spectrometer contains NaI (Tl) detector at the photon energies of 662, 1173 an...

متن کامل

Evaluation of Canonical Correlations between Masticatory Muscle Orientation and Craniodentofacial Morphology in 10-17 Year_Olds

Objectives: Different theories have been suggested to define factors involved in skeletal and craniofacial morphology. Many of these theories explain that the bone morphology is the result of the bone tissue capability to adapt in response to biomechanical forces exerted during growth. Also, it seems logical to hypothesize that there is a relationship between biomechanical connections of muscle...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 210  شماره 

صفحات  -

تاریخ انتشار 2014