Can the OCT replace functional tests such as the mfERG?

نویسنده

  • Anja Palmowski-Wolfe
چکیده

Patients with retinal problems are increasingly examined with morphologic measurements such as optic coherence imaging (OCT), which is quick and easy to administer. This might give the impression that more time-consuming functional assessments, such as electrophysiological examinations, are unnecessary. However, these tests measure different things—as Dhamdhere et al. showed in patients with diabetes. They examined 45 patients without clinically apparent retinopathy, using the multifocal ERG (mfERG) and Stratus OCT. There was no correlation between retinal thickness and either amplitude or implicit time of the mfERG, even in areas where the mfERG detected abnormal retinal function. For neuro-ophthalmological patients, it was shown that these examinations are not interchangeable but provide additional information. Using the frequency domain OCT (fdOCT), Dale et al. compared OCT findings to mfERG in 198 eyes from patients with a pathological result from a visual field examination that were referred by a neuro-ophthalmologist. Of these, 26% had a retinal problem based on mfERG and/or fdOCT. Of these eyes, both mfERG and OCT findings were abnormal in 48%. However, in about 38.5% of the eyes the mfERG was abnormal, but the fdOCT was normal. On the other hand, mfERG was normal with an abnormal fdOCT in 13.5%. A drawback of these studies was that total retinal thickness was measured. Talamini et al. studied 25 patients with abnormal mfERG and abnormal visual fields but normal appearing OCT. When the OCT was segmented further to allow analysis of different retinal layers, the sensitivity to detect retinal damage on fdOCT was increased from 0% to 60%. However, even with such a segmentation, 40% of eyes with an abnormal mfERG and abnormal visual fields still appeared normal on fdOCT. Thus these papers are important contributions in clarifying that at present functional retinal tests such as the mfERG cannot be replaced by morphometric tests such as the OCT—or vice versa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative sensitivity and specificity of 10-2 visual fields, multifocal electroretinography, and spectral domain optical coherence tomography in detecting hydroxychloroquine and chloroquine retinopathy

BACKGROUND The purpose of this study was to determine the relative sensitivity and specificity of 10-2 visual fields (10-2 VFs), multifocal electroretinography (mfERG), and spectral domain optical coherence tomography (SD-OCT) in detecting hydroxychloroquine retinopathy. METHODS A total of 121 patients taking hydroxychloroquine (n=119) or chloroquine (n=2) with 10-2 VF, mfERG, and SD-OCT test...

متن کامل

Indocyanine green-assisted epiretinal membrane peeling evaluated by optical coherence tomography and multifocal electroretinography

OBJECTIVE To evaluate the anatomical and functional outcome in eyes with indocyanine green (ICG)-assisted idiopathic epiretinal membrane (ERM) peeling by optical coherence tomography (OCT) and multifocal electroretinogram (MFERG). DESIGN Prospective, interventional, noncomparative case series. METHODS Twenty eyes of 20 patients with idiopathic ERM underwent pars plana vitrectomy and ICG-ass...

متن کامل

Functional improvement assessed by multifocal electroretinogram after Ocriplasmin treatment for vitreomacular traction

BACKGROUND To evaluate the functional recovery of patients with symptomatic vitreomacular traction (VMT) after Ocriplasmin treatment. METHODS Prospective, single centre, consecutive case series. Patients were treated with a single intravitreal injection of Ocriplasmin (Jetrea, Thrombogenics Inc, USA, Alcon/Novartis EU). The following outcome measures are considered: resolution of VMT, evaluat...

متن کامل

High-speed ultra-high-resolution optical coherence tomography findings in hydroxychloroquine retinopathy.

OBJECTIVES To compare structural changes in the retina seen on high-speed ultra-high-resolution optical coherence tomography (hsUHR-OCT) with multifocal electroretinography (mfERG) and automated visual fields in patients receiving hydroxychloroquine. METHODS Fifteen patients receiving hydroxychloroquine were evaluated clinically with hsUHR-OCT, mfERG, and automated visual fields. Six age-matc...

متن کامل

Retinal function in best macular dystrophy: relationship between electrophysiological, psychophysical, and structural measures of damage.

PURPOSE To establish structure-function correlations across the visual field, to investigate disease progression in Best macular dystrophy (BMD), by correlating structural damage with retinal function as assessed by the combination of psychophysics and multifocal electrophysiology. METHODS Spatial achromatic and chromatic contrast sensitivities (probing red-green and blue-yellow pathways) wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 10  شماره 

صفحات  -

تاریخ انتشار 2012