Precision of and new methods for testing in vitro alloy cytotoxicity.

نویسندگان

  • J C Wataha
  • R G Craig
  • C T Hanks
چکیده

Previous studies have utilized in vitro alloy cytotoxicity tests to evaluate dental casting alloys. The purposes of this study were to: (1) evaluate the precision of the optical density and visual tests previously used, (2) evaluate a new test measuring absorbance of solubilized formazan dyes, and (3) test the correlation between these tests for cytotoxicity. Balb/c 3T3 cells were plated in 24-well culture trays at 25,000 cells/cm2 around ten types of dental casting alloys (six samples/alloy) and incubated for 72 h. Cells were histochemically stained with MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide)/succinate for 2 h, then fixed, washed, and dried. Toxicity was measured by optical densitometer (OD) scanning, visual assessment, and 560-nm absorbance of DMSO-solubilized dyes. Measurements of rings of inhibition were not used, because they did not provide precise data, and correlated poorly with the other methods. The results were analyzed by ANOVA, Tukey intervals, and coefficients of variation (CV's). MTT required shorter incubation times for adequate staining, allowed for solubilization of the monolayers, and was less expensive than NBT (2,2'-di-p-nitro-phenyl-5,5'-diphenyl-3,3'-dimethoxy-[3,3'-dimethoxy-4,4 '-biphenylene] ditetrazolium chloride). Results showed that all three methods ranked alloy toxicities similarly (p = 0.05). The solubilization method was most discriminating due to lower CV's. Correlation between densitometer and solubilization methods was excellent (R2 = 0.96). Between-experiment CV's were generally less than 20%, and often less than 10%. Between-sample CV's were generally less than 20%.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی و مقایسه زیست‌سازگاری آلیاژ مینالوکس و آلیاژ مشابه خارجی (In-vitro)

Statement of Problem: One of newly presented base metal alloys (Minalux) is produced according to VeraBond2 alloy (Ni- Cr base) composition. Several studies showed that, cytotoxicity of base metal alloys can be occurred due to corrosion and element release. Purpose: This study evaluated the biocompatibility of these two base metal alloys in three steps: as cast, after polishing and after porcel...

متن کامل

A NEW CYTOCOLORIMETRIC ASSAY USING PHOSPHATAS E ACTIVI T Y FOR MEASURING CELLULAR FUNCTIONS

In this study cellular phosphatase activity, referred to as enzyme developed color (EDC) assay, was used for an in vitro assessment of cell proliferation and cytotoxicity. Optimum conditions were established and found to be 10 x103 cells / well at 37°C and 60 min incubation (for developing color). Under the same conditions a direct correlation between optical density (00) and cell number wa...

متن کامل

RGD-Modified Nano-Liposomes Encapsulated Eptifibatide with Proper Hemocompatibility and Cytotoxicity Effect

Background: Eptifibatide (Integrilin®) is a hepta-peptide drug which specifically prevents the aggregation of activated platelets. The peptide drugs are encapsulated into nanolipisomes in order to decreasing their side effects and improving their half-life and bioavailability. Objectives: In this study, the in vitro cytotoxicity and hemocompatibi...

متن کامل

Abnormal Plastic Behavior of Fine Grain Mp35n Alloy During Room Temperature Tensile Testing

In this paper, results of an investigation on the strain hardening responses of superalloy MP35N with two average grain sizes of 38 and 1 μm, during room temperature tensile testing are reported. The microstructural evolution of the deformed samples was studied using optical and transmission electron microscopy (TEM) techniques. The strain hardening behavior of the 38 μm material was rather sim...

متن کامل

Evaluation of Soldered Joints of Two Base Metal Ceramic Alloys: Supercast and Minalux

Background: Different soldering techniques have a variety of applications in dentistry. One of the most important uses of soldering is to join multiple-unit fixed partial dentures together. In this Study, two base metal alloys (Supercast and Minalux) were soldered  and their tensile, compressive and flexural strengths were measured and compared to each other. Materials and methods: In this ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 1992